Goodman GPD1436090M41
Goodman GPD1436090M41
Hover to zoom
1 Of 5

Goodman GPD14 - 92,000 BTU - Packaged Heat Pump/Furnace - NG - 80% AFUE - Two-Stage - Horizontal/Downflow

Model:

GPD1436090M41

Write A Review
Product Discontinued
Sorry, this product is no longer available.
Try this product instead
Goodman GPD14 - 92,000 BTU - Packaged Heat Pump/Furnace - NG - 80% AFUE - Two-Stage - Horizontal/Downflow
Goodman GPD14 - 92,000 BTU - Packaged Heat Pump/Furnace - NG - 80% AFUE - Two-Stage - Horizontal/Downflow
Model: GPD1436090M41
Product Discontinued
Accessories
Features
Specifications
Reviews
How-To Articles
Share

Recommended Accessories

eComfort expert image
Expert Recommended Accessories Selected by Ken, our Expert
Required Accessories 9
These accessories are required to properly setup/install this product.
Optional Accessories 10

Features

    The Goodman GPD14 packaged dual-fuel unit is designed with the famed durability and efficiency of all Goodman products in mind. A high efficiency scroll compressor and coil work in tandem to save you money on energy bills. The coil is made of refrigeration-grade copper tubing and aluminum fins in design that maximizes surface area, further enhancing efficiency. The fully-insulated blower compartment reduces the sound of the compressor, making operation quieter and less disruptive.

    Product Features

    Heavy-Gauge Galvanized Steel Cabinet
    This cabinet design is extremely durable and resistant to the elements. On top of looking modern and sleek, the design also helps in reducing the sound output of the compressor, making for a less disruptive appliance.

    EEM Motor
    EEM motors are built with multiple speeds, able to run at a gradient, or more efficient, level than PSC motors.

    Self-Diagnostics
    The blower opreation control and the safety circuits come complete with a self-diagnostic system, making troubleshooting and maintenance much simpler.

California residents see
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
For more information go to: www.p65Warnings.ca.gov

Specifications

GPD1436090M41
specs product image PID-60442
Performance
AFUE Learn More
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
80 %
Capacity Learn More
Capacity
Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
3.0 Tons
Nominal Cooling Capacity
35200 BTU
Heating BTU
92000
High Fire Output
72900 BTU
Low Fire Input
69000 BTU
Low Fire Output
55000 BTU
SEER Learn More
SEER
SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
14
EER Learn More
EER
EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
11.4
HSPF Learn More
HSPF
HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
8
Maximum Air Flow
1050 CFM
Maximum Sound Level Learn More
Maximum Sound Level
Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
76 dB
General Information
Type
Gas/Electric Packaged Unit
Product Line
GPD14
Operating Mode Learn More
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling & Heating
Gas Type
Natural Gas
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
Modulating/Staging Learn More
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Staging
Refrigerant Type
R-410A
Blower Motor Type
Multi-Speed
Motor Type
EEM
Configuration Learn More
Configuration
Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Horizontal/Downflow
Installation Location
Outdoor
Gas Conversion Kit
Available
Gas Valve Stages
Two-Stage
Compressor Stages Learn More
Compressor Stages
Stages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
Single-Stage
DOE Regional Compliance Learn More
DOE Regional Compliance
In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
10 Years
Certifications
ETL Listed
Yes
AHRI Certified
Yes
Electrical Data
Voltage
208-230 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
24.2 Amps
Recommended Breaker Size
40 Amps
Dimensions
Product Height
32 Inches
Product Width
51 Inches
Product Depth
47 Inches
Product Weight
440 Pounds
Shipping Weight
460 Pounds

Reviews

Goodman GPD1436090M41 Reviews & Ratings
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.

How-To Articles

How to Pick the Perfect City Multi Outdoor Unit
How to Pick the Perfect City Multi Outdoor Unit
When dealing with very large buildings with many different zones, choosing a hea...
On-Demand Furnace and AC Installation
On-Demand Furnace and AC Installation
eComfort Installation is the easiest, most-efficient way to get your home's air...
Smart, Safe, Clean Home Tips
Smart, Safe, Clean Home Tips
Americans are spending more time at home than ever before. It’s very like...
eComfort How-To Library
eComfort How-To Library
Articles, Tips and Buying Guides from Our Experts
 
Media Gallery
Goodman GPD14 - 92,000 BTU - Packaged Heat Pump/Furnace - NG - 80% AFUE - Two-Stage - Horizontal/Downflow
Goodman GPD1436090M41
Customer Review Images