Local Pickup FAQ's
Hover to zoom
1 Of 5
Weil-McLain GV90+ 4, High Efficiency Cast Iron Boiler - 105,000 BTU
Model:
382-200-601
+
Share This Product
Recommended Accessories
Expert Recommended Accessories
Selected by Ken, our Expert
Required Accessories
9
These accessories are required to properly setup/install this product.
Optional Accessories
10
Features
- Up to 92% AFUE efficient
- Durable cast iron primary heat exchanger
- Condensing stainless steel secondary heat exchanger
- Unique 7 pass heat exchanger design maximizes heat transfer
- Vents with PVC
- Mutiple venting options: direct vent, direct exhaust, concentric
- Easy conversion to propane-kit included
- Applications include: residential, light commercial, mutiple boilers, indirect-firedwater heating, radiant heating, and much more
- Boiler sections made from recycled metals
- Lower emission levels than most boilers
- Eligible for utility rebate programs (check your local area for details and current rebate amounts)
- GV90+ is the first cast iron boiler vented with PVC - saving 90% over the cost of stainless steel venting material per foot
- Simple diagnostics significantly reduces troubleshooting time by using flashing LED lights to communicate errors - no need to decipher codes or ready lengthy manuals
- 2 Years Parts
- 20 Years Heat Exchanger
Weil McLain GV90+ 4, High Efficiency Cast Iron Boiler - 105,000 BTU - 91.2%
When matched with a Weil-McLain indirect-fired water heater, you will experience virtually limitless hot water for bathing, laundry, dishwashing and cooking at a lower operating cost compared to most other alternatives. The heaters provide twice the peak flow of a tankless coil, 50% more than a comparable sized direct-fired gas water heater and 3 times as much as an electric unit. With boiler sections made from recycled metals and lower emmission levels than most boilders, the GV90+ is one of the greenest cast irons boilers around.
Weil McLain GV90+ 4 Features & Benefits:
California residents see
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
For more information go to: www.p65Warnings.ca.gov
Specifications
382-200-601
Performance
Maximum Input Capacity
Maximum Input Capacity
The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
105000 BTU
DOE Heating Capacity
DOE Heating Capacity
Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
97000 BTU
Net I=B=R Capacity
Net I=B=R Capacity
I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
84000 BTU
Efficiency
91.2 %
Warranty Information
Parts Warranty
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
2 Years
Heat Exchanger Warranty
20 Years
General Information
Medium
Medium
Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Fuel Type
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas (Convertible)
Combustion Type
Combustion Type
Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Conventional
Vent Type
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
DHW Production
DHW Production
DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
Yes
Modulating/Staging
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Staging
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
5500 Feet
Includes Pump
Yes
Assembly Type
Packaged
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Primary Vent Pipe Diameter
3 Inches
Supply Connection
1 Inch
Return Connection
1 Inch
Product Height
30 3/4 Inches
Product Width
24 5/8 Inches
Product Depth
30 3/4 Inches
Product Weight
353 Pounds
Reviews
Weil-McLain 382-200-601 Reviews & Ratings
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.
Please share your insights with fellow shoppers.
How-To Articles
How to Pick the Perfect City Multi Outdoor Unit
When dealing with very large buildings with many different zones, choosing a hea...
On-Demand Furnace and AC Installation
eComfort Installation is the easiest, most-efficient way to get your home's air...
Smart, Safe, Clean Home Tips
Americans are spending more time at home than ever before. It’s very like...
Ask A Question!
*Required Fields
+
Thank You For Submitting Your Question
Your submission has been sent successfully. Please give our experts up to two business days to respond.
Media Gallery
Weil-McLain GV90+ 4, High Efficiency Cast Iron Boiler - 105,000 BTU
Customer Review Images