VXT-24 Residential Steam Boiler Water Feeder, 24 VAC print

VXT-24 Residential Steam Boiler Water Feeder, 24 VAC
Click to enlarge
Product Specifications
General Data
Connection TypeSweat
Electrical Data
Power Consumption (Watts)10
Voltage (Volts)24
Frequency (Hertz)60
Dimensions
Connection Size (Inches)1/2
Product Weight (Pounds)15
Warranty
Parts Warranty (Years)1
VXT-24
Hydrolevel
Ships out within 3-5 days.

Your Price: $223.95

Checking for rebates...
Rebates for the VXT-24 Select any applicable rebates from the list below and downoad forms to fill out or mail in. If no download form is avaiable, follow the instrutions in the rebate message to register for your rebate.
Free Ground Shipping (details)
Orders of $200 or more qualify for free ground shiping within the United States, excluding Hawaii, Puerto Rico, and other areas deemed remote by our shipping carriers.
Find professional installers in your area during checkout
BBB Accredited
Amazon Payments Certified
Paypal Verified
Norton Secured
Satisfaction Guaranteed
It's important to us that you are satisfied with our products. In case you need to return a product, you may do so within 30 days of your order's delivery, often without a restocking fee. We've worked really hard to make the return experience as easy as possible. How did we do it? We put it online! More
Hydrolevel VXT-24 Residential Steam Boiler Water Feeder, 24 VAC
Product Overview

Hydrolevel VXT-24 Residential Steam Boiler Water Feeder, 24 VAC

The VXT is the first automatic steam boiler water feeder designed to monitor the amount of water added to a steam boiler. The addition of make-up water raises the oxygen level in a boiler and accumulates lime and other mineral deposits. Excessive boiler make-up water can cause cast iron boilers to rust internally, severely shortening the boiler's life. Mineral deposits from too much make-up water can impede heat transfer causing cast iron boiler sections to overheat and crack. Unlike other water feeders, the VXT can protect the life of a boiler by exposing system leaks that call for excessive make-up water – giving you the information you need to diagnose and repair the system before it's too late. VXT Steam Boiler Water Feeders are primarily used on residential and light commercial steam heating boilers up to 500,000 Net BTUH. They are not recommended for commercial steam process work.

The VXT feeder should be wired to and receive its signal from a float or probe type low water cut-off. When the VXT receives a signal from the LWCO, it initiates an adjustable delay before feed to allow condensate from the system to return to the boiler and near boiler piping. Upon completion of the delay, if the LWCO feed signal is still present, the feeder begins its feed cycle. If the feed signal is still present after the completion of the feed cycle, the control will revert back to its delay mode. After the second delay expires the control will begin another feed cycle. If the signal is still present after the second feed cycle, the control will lock-out until the feed signal from the LWCO has been removed. Once in lock-out, the feeder can be forced to feed an additional two cycles each time power is removed then reapplied. The Safgard VXT water feeder is fully programmable to accommodate any residential steam system.

Hydrolevel VXT-24 VXT Residential Steam Boiler Water Feeder Features:
  • Universal Compatibility - The VXT can be used with virtually any probe or float type low water cut-off
  • Digital Feed Counter - Displays the amount of water added to the boiler, essential in detecting boiler destroying water loss problems
  • Programmable Feed Delay - Helps prevent flooded boilers by allowing time for condensate to return to boiler before initiating a feed cycle
  • Programmable Feed Amount - Two ways to feed; gallon amount settings can feed above the probe to a working water line, and LWCO setting ends feed when LWCO reenergizes the burner
  • Underfeed Protection - If one feed cycle is not enough to restore boiler operation, the VXT will delay and feed one additional time
  • Lock-Out Flood Protection - The VXT will lock out to prevent system flooding and costly water damage if burner operation does not resume after two consecutive feed cycles
  • Manual Feed Button - Manual feed amounts are recorded and added to the gallon total displayed on counter
Hydrolevel VXT-24 VXT Residential Steam Boiler Water Feeder Warranty:
  • 1 year