Burnham ALTAC-200-1G02
Burnham ALTAC-200-1G02
Burnham ALTAC-200-1G02
Burnham ALTAC-200-1G02
Hover to zoom
1 Of 5
Burnham ALTAC-200-1G02
Burnham ALTAC-200-1G02
Burnham ALTAC-200-1G02

Burnham ALTA - 200K BTU - 95% AFUE - Combi Gas Boiler - Direct Vent

Model:

ALTAC-200-1G02

Write A Review
Product Discontinued
Sorry, this product is no longer available.
Burnham ALTA - 200K BTU - 95% AFUE - Combi Gas Boiler - Direct Vent
Burnham ALTA - 200K BTU - 95% AFUE - Combi Gas Boiler - Direct Vent
Model: ALTAC-200-1G02
Product Discontinued
Accessories
Features
Specifications
Reviews
How-To Articles
Manuals
Share

Recommended Accessories

eComfort expert image
Expert Recommended Accessories Selected by Ken, our Expert
Required Accessories 9
These accessories are required to properly setup/install this product.
Optional Accessories 10

Features

    The Burnham Alta's simplicity is unmatched in heating technology and efficiency. Their ingenuity is responsible for some of the most efficient boilers on the market today. The Alta high efficiency gas boiler is easily the most advanced boiler ever made. By reusing heat contained in the exiting flue gasses and adjusting firing based on current needs, the Alta can achieve 95 percent efficiency. The Alta's advanced technology also makes installation and operation of your boiler easier than ever. Easy lift, wall hanging design, no-touch combustion setup, and interface prompts all contribute to its ease of use. Getting the most out of your energy dollar doesn't have to be a complicated affair, and Burnham proves it with the Alta.
  • Heat Exchanger
  • 316L Stainless Steel Heat Exchanger, Corrosion resistant.
  • Sealed Combustion Appliance
  • 10:1 Turndown, Direct vent.
  • Boiler Circulator
  • Grundfos UPS-78 Special
  • Universal Vent Connection for CPVC, Polypropylene
  • 3 in 1 Air Vent Adapters with Test Port.
  • Wall Bracket Mount Kit
  • Pre-installed hanging bracket, Easy lift wall hanging design.
  • Product Note
    This product can be used with liquid propane or natural gas and is field convertible.
California residents see
Warning: This product can expose you to chemicals including Chromium (hexavalent compounds) which is known to the State of California to cause Cancer.
For more information go to: www.p65Warnings.ca.gov

Specifications

ALTAC-200-1G02
specs product image PID-124927
General Information
Product Line
Alta
Product Category
Boiler
Medium Learn More
Medium
Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Combi
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural or Propane Gas
Combustion Type Learn More
Combustion Type
Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Adaptive
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
DHW Production Learn More
DHW Production
DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
Yes
Modulating/Staging Learn More
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Modulating
Mount Type
Wall
Minimum Altitude
0 Feet
Maximum Altitude
2000 Feet
Assembly Type
Packaged
Includes Pump
Yes
Gas Conversion Kit
Included
UPC
672616844318
Performance
AFUE Learn More
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
95 %
Maximum Input Capacity Learn More
Maximum Input Capacity
The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
150000 BTU
Minimum Input Capacity
20000 BTU
DOE Heating Capacity Learn More
DOE Heating Capacity
Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
141000 BTU
Net I=B=R Capacity Learn More
Net I=B=R Capacity
I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
123000 BTU
Minimum Flow Rate
5.2 GPM
Maximum Flow Rate
4.7 GPM
Ultra Low NOx Emissions Learn More
Ultra Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Turndown Ratio
10:1
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
1/2 Inch
Flue Connection Size
2 Inches
Cold Water Inlet
1 1/4 Inches
Hot Water Outlet
1 1/4 Inches
Supply Connection
1 1/4 Inches
Return Connection
1 1/4 Inches
Product Height
30 Inches
Product Width
18 Inches
Product Depth
20 19/48 Inches
Product Weight
116 Pounds
Shipping Weight
141 Pounds
Certifications
Country of Origin
United States
ETL Listed
Yes
Energy Star Listed
Yes
ASME Certified
Yes
AHRI Certified
Yes
AHRI Reference Number
207178442
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
12 Years

Reviews

Burnham ALTAC-200-1G02 Reviews & Ratings
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.

How-To Articles

How to Pick the Perfect Boiler
How to Pick the Perfect Boiler
At the heart of every boiler heating system is the boiler itself. It's responsi...
Five Ways to Improve Boiler Efficiency
Five Ways to Improve Boiler Efficiency
When purchasing a new boiler for your home, efficiency is the name of the game....
Hydronic System Accessory Guide
Hydronic System Accessory Guide
How warm does a coat keep you without gloves and a hat? Accessories are sometim...
eComfort How-To Library
eComfort How-To Library
Articles, Tips and Buying Guides from Our Experts

Manuals

 
Media Gallery
Burnham ALTA - 200K BTU - 95% AFUE - Combi Gas Boiler - Direct Vent
Burnham ALTAC-200-1G02
Burnham ALTAC-200-1G02
Burnham ALTAC-200-1G02
Burnham ALTAC-200-1G02
Customer Review Images