Features
Specifications
Reviews
How-To Articles
Manuals
Share

Features

    Burnham Independence IN4 Gas Fired Steam Boiler, NG, Electronic Ignition, Up to 2,000 Ft Altitude, Knocked-Down - 105,000 BTU

    Burnham has had remarkable success achieving a high efficiency for its Independence line of steam boilers. With an AFUE of 83% for a steam boiler, homeowners can be assured that energy costs are as low as possible. Ranging from 62,000 BTU to 385,000 BTU, the Independence line of steam boilers can be used in a wide variety of applications. Using natural or LP gas, a direct vent or natural draft option are both acceptable choices. Cast iron sectional design ensures reliable heat transfer, and an optional water boiler allows for maximum flexibility. Burnham has been at the forefront of boiler design for decades, and the Independence boiler line is no exception to its reputation for quality, safety and efficiency.

    Burnham KIN4LNI-LL2 Gas Fired Steam Boiler Features:
    • High Efficiency up to 83% AFUE
    • Natural or LP Gas
    • Direct replacement for thousands of existing boilers
    • Natural draft or power vented
    Burnham KIN4LNI-LL2 Gas Fired Steam Boiler Additional Features:
    • Cast Iron Sectional Design
    • Optional Water Boiler Option
    • 62,000 to 385,000 BTU size choices
    • Controlled fuel management preserves fuel when burner is not active
    Burnham KIN4LNI-LL2 Gas Fired Steam Boiler Warranty:
    • Boiler Warranty: 1 Year
    • Heat Exchanger: Limited 10 Years
    • Tank Warranty: Limited 10 Years
    • Parts Warranty: Limited 1 Year
    Product Note

    Boiler trim package must be ordered separately.

California residents see
Warning: This product can expose you to chemicals including Chromium (hexavalent compounds) which is known to the State of California to cause Developmental Harm.
For more information go to: www.p65Warnings.ca.gov

Specifications

KIN4LNI-LL2
specs product image PID-37860
General Information
Medium Learn More
Medium
Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Steam
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type Learn More
Combustion Type
Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Conventional
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
DHW Production Learn More
DHW Production
DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Learn More
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
2000 Feet
Assembly Type
Knockdown
Performance
AFUE Learn More
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
82 %
Maximum Input Capacity Learn More
Maximum Input Capacity
The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
105000 BTU
DOE Heating Capacity Learn More
DOE Heating Capacity
Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
87000 BTU
Net I=B=R Capacity Learn More
Net I=B=R Capacity
I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
65000 BTU
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
5 Inches
Supply Connection
2 Inches
Return Connection
2 Inches
Product Height
40 Inches
Product Width
17 3/4 Inches
Product Depth
25 Inches
Product Weight
420 Pounds
Shipping Weight
420 Pounds
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
10 Years

Reviews

Burnham KIN4LNI-LL2 Reviews & Ratings
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.

How-To Articles

How to Pick the Perfect Boiler
How to Pick the Perfect Boiler
At the heart of every boiler heating system is the boiler itself. It's responsi...
Five Ways to Improve Boiler Efficiency
Five Ways to Improve Boiler Efficiency
When purchasing a new boiler for your home, efficiency is the name of the game....
Hydronic System Accessory Guide
Hydronic System Accessory Guide
How warm does a coat keep you without gloves and a hat? Accessories are sometim...
eComfort How-To Library
eComfort How-To Library
Articles, Tips and Buying Guides from Our Experts

Manuals

 
Media Gallery
Burnham Independence IN4 Gas Fired Steam Boiler, NG, Electronic Ignition, Up to 2,000 Ft Altitude, Knocked-Down - 105,000 BTU
Burnham KIN4LNI-LL2
Customer Review Images