Burnham SIN4LNI-LE2
Burnham SIN4LNI-LE2
Hover to zoom
1 Of 5

Burnham IN4 - 65K BTU - 82.0% AFUE - Steam Gas Boiler - Chimney Vent - Semi-Packaged - Trim Sold Separately

Model:

SIN4LNI-LE2

Write A Review
$2,926.00
Free Shipping
&
Lift Gate
  Learn More About Free Freight
Free Shipping & Lift Gate
*This product qualifies for Free Shipping anywhere in the contiguous US. Accessories may ship separately. Items over 100lbs shipped via semi-truck, be sure to select "Lift Gate" to lower the product to the ground curbside. Remote area surcharges may apply, see our full shipping policy for more details.
In-Stock
Ships Monday, Dec 23rd
Shipping to60601
synchrony card logo
$52 / Month
With our 86 months 11.99% APR*
86 fixed monthly payments required.
Burnham IN4 - 65K BTU - 82.0% AFUE - Steam Gas Boiler - Chimney Vent - Semi-Packaged - Trim Sold Separately
Burnham IN4 - 65K BTU - 82.0% AFUE - Steam Gas Boiler - Chimney Vent - Semi-Packaged - Trim Sold Separately
Model: SIN4LNI-LE2
$2,926.00
Accessories
Features
Specifications
Reviews
Product Q&A
How-To Articles
Manuals
Share

Recommended Accessories

eComfort expert image
Expert Recommended Accessories Selected by Ken, our Expert
Required Accessories 9
These accessories are required to properly setup/install this product.
Optional Accessories 10

Features

    Burnham is devoted to pushing the limits of heating technology and efficiency. Their ingenuity is responsible for some of the most efficient boilers on the market today. The Independence line brings reliability and simplicity to the forefront. Burnham's Independence boilers are an efficient, low profile solution for your hydronic heating needs. The large water volume of Independence boilers means that they are suited for a variety of applications. The SIN4LNI-LE2 has an insulated jacket that covers the gas valves and burner to improve not just heat retention and efficiency but safety as well. High quality Honeywell controls are also concealed within the jacket. If you are looking for a well-rounded, dependable steam boiler, you don't need to look further than the Independence.
  • Low Profile Venting
  • The SIN4LPI-LE2's draft hood is smaller than natural draft boilers, and is shifted to the rear of the unit to save space. The Independence's low profile provides flexibility and makes it an ideal replacement boiler for all sorts of installations.
  • Durable Construction
  • Cast-iron construction of the boiler sections and stainless steel burners contribute to the incredible longevity of Independence models. The heat exchanger is also made of cast iron, which allows it to accept lower return water temperatures.
  • Product Includes
  • (1) Burnham SIN4LNI-LE2 Steam Boiler
  • (1) Burnham 8116322 5" Vent Damper
  • (1) Instruction Envelope

Specifications

SIN4LNI-LE2
specs product image PID-105247
General Information
Product Line
Independence
Medium Learn More
Medium
Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Steam
Heat Exchanger Material
Cast Iron
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type Learn More
Combustion Type
Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Conventional
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
DHW Production Learn More
DHW Production
DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Learn More
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Staging
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
2000 Feet
Includes Pump
No
Assembly Type
Semi-Packaged
Gas Conversion Kit
Available
Performance
AFUE Learn More
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
82 %
Maximum Input Capacity Learn More
Maximum Input Capacity
The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
105000 BTU
DOE Heating Capacity Learn More
DOE Heating Capacity
Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
87000 BTU
Net I=B=R Capacity Learn More
Net I=B=R Capacity
I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
65000 BTU
Ultra Low NOx Emissions Learn More
Ultra Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
5 Inches
Gas Connection Size
1/2 Inch
Supply Connection
2 Inches
Return Connection
2 Inches
Product Height
40 Inches
Product Width
17 3/4 Inches
Product Depth
25 Inches
Shipping Weight
420 Pounds
Certifications
Country of Origin
United States
AHRI Certified
Yes
AHRI Reference Number
2101400
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
10 Years

Reviews

Burnham SIN4LNI-LE2 Reviews & Ratings
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.

Product Q&A

Expert avatar photo
Be the First to Ask A Question Answered by Ken, the eComfort Product Expert

How-To Articles

How to Pick the Perfect Boiler
How to Pick the Perfect Boiler
At the heart of every boiler heating system is the boiler itself. It's responsi...
Five Ways to Improve Boiler Efficiency
Five Ways to Improve Boiler Efficiency
When purchasing a new boiler for your home, efficiency is the name of the game....
Hydronic System Accessory Guide
Hydronic System Accessory Guide
How warm does a coat keep you without gloves and a hat? Accessories are sometim...
eComfort How-To Library
eComfort How-To Library
Articles, Tips and Buying Guides from Our Experts

Manuals

 
Media Gallery
Burnham IN4 - 65K BTU - 82.0% AFUE - Steam Gas Boiler - Chimney Vent - Semi-Packaged - Trim Sold Separately
Burnham SIN4LNI-LE2
Customer Review Images