Burnham X203PTH
Burnham X203PTH
Hover to zoom
1 Of 5

Burnham X-2 - 59K BTU - 84% AFUE - Hot Water Propane Boiler - Chimney Vent

Model:

X203PTH

Write A Review
$2,393.84
Free Shipping
&
Lift Gate
  Learn More About Free Freight
Free Shipping & Lift Gate
*This product qualifies for Free Shipping anywhere in the contiguous US. Accessories may ship separately. Items over 100lbs shipped via semi-truck, be sure to select "Lift Gate" to lower the product to the ground curbside. Remote area surcharges may apply, see our full shipping policy for more details.
Factory-Direct
Ships in 3-4 Weeks
synchrony card logo
$399 / Month
Suggested monthly payments with 6 month financing.
Burnham X-2 - 59K BTU - 84% AFUE - Hot Water Propane Boiler - Chimney Vent
Burnham X-2 - 59K BTU - 84% AFUE - Hot Water Propane Boiler - Chimney Vent
Model: X203PTH
$2,393.84
Accessories
Features
Specifications
Reviews
Product Q&A
How-To Articles
Manuals
Share

Recommended Accessories

eComfort expert image
Expert Recommended Accessories Selected by Ken, our Expert
Required Accessories 9
These accessories are required to properly setup/install this product.
Optional Accessories 10

Features

    The Burnham X-2 Series boiler is a well-made and reliable cast iron water boiler. Because it's made in the USA, you know you are getting quality product that will last. The X-2 comes equipped with a circulator - your choice between a Taco or Grundfos. Another added feature is a pre-installed low water cut off, protecting your boiler from damage if the water level gets too low. Popular for direct replacements, the X-2 offers industry standard tapping locations for easy compatibility and replacement for your existing boiler.
  • Fully Featured
  • The Burnham X-2 comes fully featured with a Taco circulator and pre-installed low water cut off (LWCO). A LWCO is vital, preventing damage or even an explosion in the event of low water levels in your boiler.
  • Durable Construction
  • An American-made cast iron heat exchanger, insulated steel jacket, and 1 of heavy gauge insulation all contribute to the longevity of the X-2."
  • Integrated Controls
  • Concealed within the boiler jacket, an integrated boiler control with a self-diagnostic control system give you a digital readout for status and errors.
  • Product Includes
  • (1) Burnham X-203 Hot Water Propane Boiler
  • (1) Taco Circulator
  • Product Note
    A high altitude conversion kit is required for installations made at altitudes above 5,400'.
California residents see
Warning: This product can expose you to chemicals including Chromium (hexavalent compounds) which is known to the State of California to cause Developmental Harm.
For more information go to: www.p65Warnings.ca.gov

Specifications

X203PTH
specs product image PID-82218
Overview
Product Category
Boiler
Additional Model Numbers

X-203P-TH, X203PTH

General Information
Product Line
X-2
Product Category
Boiler
Medium Learn More
Medium
Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Cast Iron
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Liquid Propane
Combustion Type Learn More
Combustion Type
Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Conventional
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
DHW Production Learn More
DHW Production
DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Learn More
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Staging
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
10000 Feet
Includes Pump
Yes
Assembly Type
Packaged
Performance
AFUE Learn More
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
84 %
Maximum Input Capacity Learn More
Maximum Input Capacity
The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
70000 BTU
DOE Heating Capacity Learn More
DOE Heating Capacity
Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
59000 BTU
Net I=B=R Capacity Learn More
Net I=B=R Capacity
I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
51000 BTU
Ultra Low NOx Emissions Learn More
Ultra Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
1/2 Inch
Flue Connection Size
4 Inches
Supply Connection
1 1/4 Inches
Return Connection
1 1/4 Inches
Product Height
40 Inches
Product Width
14 Inches
Product Depth
33 1/4 Inches
Shipping Weight
254 Pounds
Certifications
Energy Star Listed
Yes
ETL Listed
Yes
ASME Certified
Yes
AHRI Certified
Yes
AHRI Reference Number
8330975
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
10 Years

Reviews

Burnham X203PTH Reviews & Ratings
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.

Product Q&A

Expert avatar photo
Be the First to Ask A Question Answered by Ken, the eComfort Product Expert

How-To Articles

How to Pick the Perfect Boiler
How to Pick the Perfect Boiler
At the heart of every boiler heating system is the boiler itself. It's responsi...
Five Ways to Improve Boiler Efficiency
Five Ways to Improve Boiler Efficiency
When purchasing a new boiler for your home, efficiency is the name of the game....
Hydronic System Accessory Guide
Hydronic System Accessory Guide
How warm does a coat keep you without gloves and a hat? Accessories are sometim...
eComfort How-To Library
eComfort How-To Library
Articles, Tips and Buying Guides from Our Experts

Manuals

 
Media Gallery
Burnham X-2 - 59K BTU - 84% AFUE - Hot Water Propane Boiler - Chimney Vent
Burnham X203PTH
Customer Review Images