Crown Boiler Co. CWI207ENTT1PSU
Crown Boiler Co. CWI207ENTT1PSU
Hover to zoom
1 Of 5

Crown Boiler Cayman - 173K BTU - 83.2% AFUE - Hot Water Gas Boiler - Chimney Vent - Includes DHW Coil

Model:

CWI207ENTT1PSU

Write A Review
Product Discontinued
Sorry, this product is no longer available.
Crown Boiler Cayman - 173K BTU - 83.2% AFUE - Hot Water Gas Boiler - Chimney Vent - Includes DHW Coil
Crown Boiler Cayman - 173K BTU - 83.2% AFUE - Hot Water Gas Boiler - Chimney Vent - Includes DHW Coil
Model: CWI207ENTT1PSU
Product Discontinued
Accessories
Features
Specifications
Reviews
How-To Articles
Manuals
Share

Recommended Accessories

eComfort expert image
Expert Recommended Accessories Selected by Ken, our Expert
Required Accessories 9
These accessories are required to properly setup/install this product.
Optional Accessories 10

Features

    Crown's Cayman line of boilers is designed to be an all-encompassing heating solution for homes ranging in size from a small condo to a full multi-bedroom household. The heat exchanger at its core is constructed of cast-iron, a material proven effective in hundreds of heating applications around the world. The footprint of the Cayman is smaller than average making it perfect for compact utility rooms, and it comes with a low-clearance vent opening to maximize venting flexibility and installation options. The key feature of the Cayman line is the included tankless water heater coil, an internal accessory that allows the boiler to provide domestic hot water for showers and kitchen needs while heating the air in your home at the same time.
  • Cast Iron Heat Exchanger
  • The heat exchanger at the core of the Cayman is made of durable cast iron, a material proven many times over for its reliability in heating applications and efficiency in heat transfer.
  • Built-In Tankless Coil
  • The Crown Cayman boilers come with a built-in tankless water heater coil, allowing the boiler to handle all of your domestic hot water needs without an external hot water tank. This also means that your home has an endless supply of hot water.
  • Low Clearance Draft Diverter
  • Crown's Cayman line of boilers come with a very low height draft diverter, allowing it to be installed in low height areas or in areas with complicated venting configurations.
  • Included Automatic Vent Damper
  • An automatic vent damper is included with the Cayman boilers. It regulates the exhaust gas flow from your boilers venting system, allowing more heat to be kept inside the boiler for increased efficiency.
California residents see
Warning: This product can expose you to chemicals including Chromium (hexavalent compounds) which is known to the State of California to cause Cancer.
For more information go to: www.p65Warnings.ca.gov

Specifications

CWI207ENTT1PSU
specs product image PID-24086
General Information
Product Line
Cayman
Medium Learn More
Medium
Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Cast Iron
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type Learn More
Combustion Type
Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Conventional
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
DHW Production Learn More
DHW Production
DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
Yes
Modulating/Staging Learn More
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
2000 Feet
Assembly Type
Packaged
Includes Pump
Yes
Performance
AFUE Learn More
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
83.2 %
Maximum Input Capacity Learn More
Maximum Input Capacity
The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
207000 BTU
DOE Heating Capacity Learn More
DOE Heating Capacity
Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
173000 BTU
Net I=B=R Capacity Learn More
Net I=B=R Capacity
I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
150000 BTU
Ultra Low NOx Emissions Learn More
Ultra Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
7 Inches
Supply Connection
1 1/4 Inches
Return Connection
1 1/4 Inches
Product Height
40 7/16 Inches
Product Width
25 3/4 Inches
Product Depth
30 Inches
Product Weight
382 Pounds
Certifications
Country of Origin
United States
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
2100221
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
20 Years

Reviews

Crown Boiler Co. CWI207ENTT1PSU Reviews & Ratings
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.

How-To Articles

How to Pick the Perfect Boiler
How to Pick the Perfect Boiler
At the heart of every boiler heating system is the boiler itself. It's responsi...
Five Ways to Improve Boiler Efficiency
Five Ways to Improve Boiler Efficiency
When purchasing a new boiler for your home, efficiency is the name of the game....
Hydronic System Accessory Guide
Hydronic System Accessory Guide
How warm does a coat keep you without gloves and a hat? Accessories are sometim...
eComfort How-To Library
eComfort How-To Library
Articles, Tips and Buying Guides from Our Experts

Manuals

 
Media Gallery
Crown Boiler Cayman - 173K BTU - 83.2% AFUE - Hot Water Gas Boiler - Chimney Vent - Includes DHW Coil
Crown Boiler Co. CWI207ENTT1PSU
Customer Review Images