Goodman GME950603BX
Goodman GME950603BX
Hover to zoom
1 Of 5

Goodman GME95 - 60,000 BTU - Gas-Fired Furnace - NG - 95% AFUE - Two-Stage - Upflow/Horizontal - Multi-Speed

Model:

GME950603BX

Write A Review
Product Discontinued
Sorry, this product is no longer available.
Try this product instead
Goodman GME95 - 60,000 BTU - Gas-Fired Furnace - NG - 95% AFUE - Two-Stage - Upflow/Horizontal - Multi-Speed
Goodman GME95 - 60,000 BTU - Gas-Fired Furnace - NG - 95% AFUE - Two-Stage - Upflow/Horizontal - Multi-Speed
Model: GME950603BX
Product Discontinued
Accessories
Features
Specifications
Reviews
How-To Articles
Manuals
Share

Recommended Accessories

eComfort expert image
Expert Recommended Accessories Selected by Ken, our Expert
Required Accessories 9
These accessories are required to properly setup/install this product.
Optional Accessories 10

Features

    The Goodman GME95 two-stage gas furnace typically runs up to 90% of the time at a low speed that maintains the temperature of your home on most days. Traditional, single stage furnaces only operate in binary fashion, on or off. Two stage furnaces such as this one, typically have three modes, off, low, and high. This gives the furnace the best of low level heating efficiency while still having the capability of quietly ramping up the temperature on more extremely cold days. This efficiency directly translates to consumer savings. 95 cents of every dollar directly translates to warming your home.

    Product Features

    Aluminized-Steel Primary Tubular Heat Exchanger
    The dual-diameter configuration, built from quality, heat-efficient materials, contributes to the high efficiency of the furnace. This configuration results in a reliable, durable, and energy-saving furnace that will last for years to come.

    Electric Control Board
    This control system comes with self-diagnostics, making troubleshooting and ongoing maintenance simplified.

    Factory Tested
    This furnace is factory tested to ensure there are no problems with the construction. This extra care, plus Goodman's long-term warranty, can guarantee that your furnace will function exactly as it should.

California residents see
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
For more information go to: www.p65Warnings.ca.gov

Specifications

GME950603BX
specs product image PID-60419
General Information
Type
Gas Furnace
Product Line
GME95
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Learn More
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Staging
Blower Motor Type
Multi-Speed
Motor Type
EEM
Configuration Learn More
Configuration
Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Horizontal
Gas Conversion Kit
Available
Gas Valve Stages
Two-Stage
DOE Regional Compliance Learn More
DOE Regional Compliance
In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide (Except CA)
Installation Available
No
UPC
663051484535
Performance
AFUE Learn More
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
95 %
Heating BTU
60000
High Fire Output
57700 BTU
Maximum Air Flow
1200 CFM
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
9.2 Amps
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
2 Inches
Product Height
40 3/4 Inches
Product Width
17 1/2 Inches
Product Depth
28 3/4 Inches
Shipping Weight
124 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
10 Years

Reviews

(2)
Goodman GME950603BX Reviews & Ratings

How-To Articles

How Gas Furnaces Work
How Gas Furnaces Work
Do you wish you had a better grasp on things when the heat goes out and your fa...
Choosing Between a Furnace and a Heat Pump
Choosing Between a Furnace and a Heat Pump
The battle between furnaces and heat pumps is hot right now. Although most Amer...
How to Pick the Perfect Furnace
How to Pick the Perfect Furnace
The heart of nearly every forced air heating system is the furnace. Gas furnace...
eComfort How-To Library
eComfort How-To Library
Articles, Tips and Buying Guides from Our Experts

Manuals

 
Media Gallery
Goodman GME95 - 60,000 BTU - Gas-Fired Furnace - NG - 95% AFUE - Two-Stage - Upflow/Horizontal - Multi-Speed
Goodman GME950603BX
Customer Review Images