Goodman GMVM96 - 60,000 BTU - Gas-Fired Furnace - NG - 96% AFUE - Modulating - Upflow/Horizontal - Variable-Speed
Model:
GMVM960603BX
+
Share This Product
Recommended Accessories
Expert Recommended Accessories
Selected by Ken, our Expert
Required Accessories
9
These accessories are required to properly setup/install this product.
Optional Accessories
10
Features
- Aluminized-Steel Primary Tubular Heat Exchanger
- The dual-diameter configuration, built from quality, heat-efficient materials, contributes to the high efficiency of the furnace. This configuration results in a reliable, durable, and energy-saving furnace that will last for years to come.
- Quiet Variable Speed Circulator Motor
- The ability to precisely adjust the speed of the motor allows for efficient use of the warm air generated. A consistent, lower speed is instrumental in the prevention of cold periods between warming cycles that occur in traditional furnaces.
- Factory Tested
- This furnace is factory tested to ensure there are no problems with the construction. This extra care, plus Goodman's long-term warranty, can guarantee that your furnace will function exactly as it should.
- ComfortBridge Communications System
- The ComfortBridge system is a total control electronic system between your air conditioner, thermostat, and any other parts of your home environment control system. This system is an intuitive and elegant control scheme for residential use.
The Goodman GMVM96 modulating gas furnace typically runs at incredibly low speeds to precisely maintain a constant, steady temperature in your home. Modulating gas valve furnaces with variable speed blowers are superior to staged gas valve and multi-speed furnaces with fuel efficiency and prevention of cold zones. Because this furnace runs at a consistently low level, it is able to run at a higher efficiency than a traditional furnace. This efficiency directly translates to consumer savings. 96 cents of every dollar directly translates to warming your home.
California residents see
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
For more information go to: www.p65Warnings.ca.gov
Specifications
GMVM960603BX
General Information
Type
Gas Furnace
Product Line
GMVM96
Fuel Type
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Modulating
Blower Type
Blower Type
Blower type describes the motor that powers the fan in the unit. PSC multi-speed is the standard motor that operates with pre-set fan speed levels. ECM multi-speed are more efficient but still operate with pre-set fan speeds. Finally, ECM variable-speed motors are also energy efficient and automatically adjust to changing system conditions.
ECM Variable-Speed
Configuration
Configuration
Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Horizontal
Gas Conversion Kit
Available
Gas Valve Stages
Modulating
DOE Regional Compliance
DOE Regional Compliance
In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide (Except CA)
Installation Available
No
UPC
663051472211
Performance
AFUE
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
96 %
Heating BTU
60000
High Fire Output
57600 BTU
Low Fire Input
30000 BTU
Low Fire Output
28800 BTU
Maximum Air Flow
1200 CFM
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
6 Amps
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
2 Inches
Product Height
40 3/4 Inches
Product Width
17 1/2 Inches
Product Depth
28 3/4 Inches
Shipping Weight
135 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
Warranty Information
Parts Warranty
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
10 Years
Reviews
(3)
Goodman GMVM960603BX Reviews & Ratings
How-To Articles
How Gas Furnaces Work
Do you wish you had a better grasp on things when the heat goes out and your fa...
Choosing Between a Furnace and a Heat Pump
The battle between furnaces and heat pumps is hot right now. Although most Amer...
How to Pick the Perfect Furnace
The heart of nearly every forced air heating system is the furnace. Gas furnace...
Manuals
Ask A Question!
*Required Fields
+
Thank You For Submitting Your Question
Your submission has been sent successfully. Please give our experts up to two business days to respond.
Media Gallery
Goodman GMVM96 - 60,000 BTU - Gas-Fired Furnace - NG - 96% AFUE - Modulating - Upflow/Horizontal - Variable-Speed
Customer Review Images