Local Pickup FAQ's
Hover to zoom
1 Of 5
Kohler RDT Series 400-Amp Automatic Transfer Switch (Service Disconnect)
Model:
RDT-CFNC-400ASEQS5
+
Share This Product
Recommended Accessories
Expert Recommended Accessories
Selected by Ken, our Expert
Required Accessories
9
These accessories are required to properly setup/install this product.
Optional Accessories
10
Features
- Standard Features
- Service Entrance Rated
- UL listed
- Two-pole, single-phase, open-transition transfer switch
- Double throw inherently interlocked design
- Solid Neutral
- 220/240 VAC, 50/60 Hz (jumper)
- Contractor manually operable for maintenance purposes
- NEMA 3R (outdoor) enclosure
- MPAC™ 500 Controller Features
- User-friendly interface and easy-to-find international symbols
- LED indication of system faults
- Test button (with or without load)
- Exercise set button
- Single-phase voltage sensing on both sources
- Line-to-line frequency sensing
- Fixed time delays
- 5-year limited warranty
California residents see
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
For more information go to: www.p65Warnings.ca.gov
Specifications
RDT-CFNC-400ASEQS5
General Information
Product Category
Generator Transfer Switches
Overview
Product Category
Generator Transfer Switches
Weight
101 Pounds
Consumer Warranty
5 Years
Product Depth
12.9 Inches
Product Width
24.7 Inches
Product Height
57 Inches
UPC
650531171955
Additional Model Numbers
RDT-CFNC-0400ASE, RDT-CFNC-400ASEQS5
Product Specs
Voltage
120/240 Single-Phase
Frequency
60 Hertz
Rated Amps
400 Amps
Enclosure
NEMA 3R
Transfer Switch Style
Service Disconnect
ATS Load Prioritizing
Not Included
ATS Load Shedding
Not Included
ATS Poles
2 Poles
ATS Service Disconnect
Yes
Max Utility Input
400 Amps
Max Generator Input
400 Amps
Maximum Wattage
96000 Watts
UL Listed
Yes
Reviews
(1)
Kohler RDT-CFNC-400ASEQS5 Reviews & Ratings
Product Q&A
(1)
Product Questions
Answered by Ken, the eComfort Product Expert
Hey Jim, I'm upgrading my service to a 400 amp. and while doing so would like to install a transfer switch. I'm looking at the Generac @ RTSD400A3, it seens to have some nice features and would fit nicely in the space available. The Generator would be installed later. Would this unit be compatible with all generator manufactures? I like Kolher generators would there be any issues? Thanks
Randy Stubbs
from Maryland
February 24, 2012
How-To Articles
Manuals
Ask A Question!
*Required Fields
+
Thank You For Submitting Your Question
Your submission has been sent successfully. Please give our experts up to two business days to respond.
Media Gallery
Kohler RDT Series 400-Amp Automatic Transfer Switch (Service Disconnect)
Customer Review Images