- 3-Pass Cast Iron Heat Exchanger
- The heat exchanger in New Yorker CI-HGS-B boilers is formed of three durable cast iron sections. Inside of this heat exchanger the water line passes over the combustion gas chamber three times, ensuring that every possible BTU is used to heat your home.
- Steel-Nipple Joints
- The three sections of the heat exchanger are joined together with steel nipples instead of traditional rubber, providing protection against normally corrosive chemicals such as antifreeze.
- Beckett AFG Oil Burner
- This CI-HGS-B boiler comes with a Beckett AFG oil burner, a high quality, robust burner that has stood the test of time in thousands of installations all across the world.
- Insulated Jacket
- The insulated jacket of the CI-HGS-B reduces standby heat loss inside of the boiler, increasing overall efficiency.
- Product Includes
- Honeywell L7248 Electronic High Limit Aquastat
- Provisions for Optional Plug-In Accessories
- Beckett NX Burner
The New Yorker CI-HGS-B line of boilers brings high efficiency oil heat to homes around the globe for an affordable price. The unique three-pass heat exchanger brings an unprecedented level of efficiency to oil boilers, using every last possible BTU out of flue gases to heat your home. Steel nipples ensure that the heat exchanger lasts the life of the boiler, while the durable insulated jacket keeps heat inside of the boiler during downtime. The included Beckett AFG oil burner has proven itself reliable in thousands of installations around the globe, adding to the already noteworthy reliability of the CI-HGS-B boiler.
California residents see
Warning: This product can expose you to chemicals including Chromium (hexavalent compounds) which is known to the State of California to cause Cancer.
For more information go to: www.p65Warnings.ca.gov
Specifications
CI-HGS-101B-LB
General Information
Product Line
CI-HGS
Medium
Medium
Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Cast Iron
Fuel Type
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Oil
Combustion Type
Combustion Type
Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Conventional
Vent Type
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
DHW Production
DHW Production
DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Mount Type
Floor
Maximum Altitude
2000 Feet
Includes Pump
No
Assembly Type
Packaged
Burner Model
Beckett NX
Performance
AFUE
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
87 %
Input Rate
0.82 GPH
DOE Heating Capacity
DOE Heating Capacity
Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
101000 BTU
Net I=B=R Capacity
Net I=B=R Capacity
I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
87000 BTU
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Dimensions
Fluid Content
7.7 Gallons
Flue Connection Size
6 Inches
Supply Connection
1 1/2 Inches
Return Connection
1 1/4 Inches
Product Height
31 3/8 Inches
Product Width
20 3/4 Inches
Product Depth
17 Inches
Product Weight
430 Pounds
Certifications
Country of Origin
United States
Energy Star Listed
Yes
ETL Listed
Yes
ASME Certified
Yes
AHRI Certified
Yes
IBR Listed
Yes
Warranty Information
Parts Warranty
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
Limited Lifetime Years
Reviews
(1)
New Yorker CI-HGS-101B-LB Reviews & Ratings
How-To Articles
How to Pick the Perfect Boiler
At the heart of every boiler heating system is the boiler itself. It's responsi...
Five Ways to Improve Boiler Efficiency
When purchasing a new boiler for your home, efficiency is the name of the game....
Hydronic System Accessory Guide
How warm does a coat keep you without gloves and a hat? Accessories are sometim...
Manuals
Ask A Question!
*Required Fields
+
Thank You For Submitting Your Question
Your submission has been sent successfully. Please give our experts up to two business days to respond.
Media Gallery
New Yorker CI-HGS-101B - 101K BTU - 87.0% AFUE - Hot Water Oil Boiler - Chimney Vent
Customer Review Images