Local Pickup FAQ's
On Sale
Hover to zoom
1 Of 5
Revolv MG2S - 72k BTU - Two-Stage Gas Furnace - Manufactured Home - 96% AFUE - Front Return - Includes Coil Cabinet
Model:
MG2S-072F
+
Share This Product
Recommended Accessories
Expert Recommended Accessories
Selected by Ken, our Expert
Required Accessories
9
These accessories are required to properly setup/install this product.
Optional Accessories
10
Features
- High Efficiency Heating
- Revolv MG2S furnaces are designed to save you money. Sporting a 96% AFUE efficiency rating, Revolv's high efficiency line will provide heat while keeping money in your pocket.
- 2-Stage Gas Valve
- A 2-stage gas valve allows for low fire-rate furnace operation to run at as little as half of the rated full capacity, preventing short cycling and reducing energy costs.
- ECM Motor
- The MG2S includes a high efficiency ECM blower motor, granting powerful CFM ratings at the fraction of the energy costs of traditional PSC motors.
Revolv is dedicated to bringing efficient comfort to the manufactured and mobile home market. The MG2S is a downflow gas furnace capable of providing 72,000 BTU of heating at 96% AFUE. Designed for easy installation in a variety of manufactured and modular homes, the MG2S features a small footprint and is HUD-compliant. The MG2S includes a 2-stage gas valve, allowing the furnace to produce as little as half the rated full-capacity to prevent short cycling and reduce energy consumption. Featuring a factory-installed coil box, the MG2S is ready to pair with an AC unit out of the box. With durable construction and a dependable warranty, the Revolv MG2S is a reliable solution for your manufactured home heating needs.
California residents see
Warning: This product can expose you to chemicals including Lead which is known to the State of California to cause Developmental Harm.
For more information go to: www.p65Warnings.ca.gov
Specifications
MG2S-072F
Overview
Product Category
Furnace
UPC
663132369973
General Information
Type
Gas Furnace
Product Line
MG2S
Product Category
Furnace
Fuel Type
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Two Stage
Blower Motor Type
ECM Fixed Speed
Configuration
Configuration
Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
Gas Conversion Kit
Included
Performance
AFUE
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
96 %
Heating BTU
72000
High Fire Input
72000 BTU
High Fire Output
69100 BTU
Low Fire Input
47000 BTU
Low Fire Output
45100 BTU
Maximum Air Flow
1633 CFM
Ultra Low NOx Emissions
Ultra Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Low NOx Emissions
Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
2 or 3 Inches
Gas Connection Size
1/2 Inch
Cabinet Width
19 7/8 Inches
Product Height
76 Inches
Product Width
19 7/8 Inches
Product Depth
24 5/8 Inches
Shipping Weight
186 Pounds
Certifications
AHRI Certified
Yes
AHRI Reference Number
203049801
Warranty Information
Parts Warranty
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
2 Years
Reviews
Revolv MG2S-072F Reviews & Ratings
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.
Please share your insights with fellow shoppers.
Product Q&A
Be the First to Ask A Question
Answered by Ken, the eComfort Product Expert
How-To Articles
How Gas Furnaces Work
Do you wish you had a better grasp on things when the heat goes out and your fa...
Choosing Between a Furnace and a Heat Pump
The battle between furnaces and heat pumps is hot right now. Although most Amer...
How to Pick the Perfect Furnace
The heart of nearly every forced air heating system is the furnace. Gas furnace...
Manuals
Ask A Question!
*Required Fields
+
Thank You For Submitting Your Question
Your submission has been sent successfully. Please give our experts up to two business days to respond.
Media Gallery
Revolv MG2S - 72k BTU - Two-Stage Gas Furnace - Manufactured Home - 96% AFUE - Front Return - Includes Coil Cabinet