Features
- Corrosion Resistant Finish
- Revolv sweat fit heat pumps are made with galvanized steel and a polyester urethane coat, creating a durable and corrosion resistant finish.
- Composite Base Pan
- A composite base pan is stronger and lighter than your standard steel base pan. Being composite, it absorbs sound better while remaining corrosion resistant.
- High Efficiency Heating
- Revolv MG2R furnaces are designed to save you money. Sporting a 95% AFUE efficiency rating, Revolv's high efficiency line will provide powerful heating while keeping money in your pocket.
- ECM Motor
- An included high efficiency, multi-speed ECM blower motor grants powerful CFM ratings at the fraction of the energy costs of traditional PSC motors.
- Category IV Venting
- The MG2R's efficient technology allows for vertical or horizontal direct venting using approved non-metallic components for application flexibility.
- 10 Year Limited Warranty
- Register your system on stylecrestinc.com within 60 days of installation to extend the Parts-Only warranty coverage to 10 years.
- (1) Revolv 3.5 Ton - Heat Pump - Manufactured Home - 14.3 SEER2 - Single-Stage - R-410A Refrigerant (RSH3ME4M1SP42)
- (1) Revolv MG2R - 45k BTU - Gas Furnace - Manufactured Home - 95% AFUE - Front Return - Includes Coil Cabinet (MG2R-045FC)
- (1) Revolv - 3.5 Ton - Upflow/Downflow Micro-Channel A-Coil - Uncased (C84DAMX42U-B)
Revolv is dedicated to bringing efficient comfort to the manufactured and mobile home market. Designed for easy installation in mobile and manufactured housing, these units are specifically designed to fit into tight spaces and operate with minimum combustion clearances. A cost-efficient solution to cooling and heating your home, this kit includes a 14.3 SEER2 heat pump paired with a powerful gas furnace. With their low cost and compact design, Revolv heating and cooling systems are the perfect match for your mobile or manufactured home.
Product Includes
California residents see
Warning: This product can expose you to chemicals including Lead which is known to the State of California to cause Developmental Harm.
For more information go to: www.p65Warnings.ca.gov
Specifications
Product Includes
- (1) Revolv 3.5 Ton - Heat Pump - Manufactured Home - 14.3 SEER2 - Single-Stage - R-410A Refrigerant (RSH3ME4M1SP42)
- (1) Revolv MG2R - 45k BTU - Gas Furnace - Manufactured Home - 95% AFUE - Front Return - Includes Coil Cabinet (MG2R-045FC)
- (1) Revolv - 3.5 Ton - Upflow/Downflow Micro-Channel A-Coil - Uncased (C84DAMX42U-B)
RSH3ME42MG2R-045F
General Information
Product Category
Furnace & Heat Pump Package
Vent Type
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Refrigerant Type
R-410A
Stages
Single
Blower Motor Type
ECM Multi-Speed
Connection Type
Sweat
Installation Location
Outdoor
DOE Regional Compliance
DOE Regional Compliance
In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Performance
AFUE
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
95 %
Capacity
Capacity
Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
3.5 Tons
Heating BTU
45000
SEER2
SEER2
The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. SEER2 (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER2, the more energy efficient the system.
14.3
EER2
EER2
The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. EER2 (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER2, the more efficient the system.
11.8
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Dimensions
Suction Connection Size
7/8 Inch
Liquid Connection Size
3/8 Inch
Certifications
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
209851999
Warranty Information
Parts Warranty
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Yr Limited Years
RSH3ME4M1SP42
General Information
Type
Heat Pump Condenser
Product Category
Heat Pump
Operating Mode
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Refrigerant Type
R-410A
Connection Type
Sweat
Installation Location
Outdoor
Compressor Stages
Compressor Stages
Stages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
Single Stage
DOE Regional Compliance
DOE Regional Compliance
In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Performance
Capacity
Capacity
Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
3.5 Tons
Cooling Capacity
39000 BTU
Heating Capacity
41000 BTU
Maximum Sound Level
Maximum Sound Level
Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
79 dB
SEER2
SEER2
The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. SEER2 (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER2, the more energy efficient the system.
14.3
EER2
EER2
The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. EER2 (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER2, the more efficient the system.
11.8
Electrical Data
Voltage
208/238 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
40 Amps
Dimensions
Suction Connection Size
7/8 Inch
Liquid Connection Size
3/8 Inch
Product Height
45 1/4 Inches
Product Width
31 3/4 Inches
Product Depth
31 3/4 Inches
Shipping Weight
201 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
Warranty Information
Parts Warranty
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
MG2R-045FC
General Information
Type
Gas Furnace
Product Line
MG2R
Product Category
Furnace
Fuel Type
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Blower Motor Type
ECM Multi-Speed
Configuration
Configuration
Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
Gas Conversion Kit
Included
Performance
AFUE
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
95 %
Heating BTU
45000
High Fire Input
45000 BTU
High Fire Output
42750 BTU
Maximum Air Flow
1605 CFM
Ultra Low NOx Emissions
Ultra Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Low NOx Emissions
Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
20 Amps
Dimensions
Gas Connection Size
1/2 Inch
Flue Connection Size
2 or 3 Inches
Cabinet Width
19 7/8 Inches
Product Height
82 Inches
Product Width
19 3/4 Inches
Product Depth
23 3/4 Inches
Shipping Weight
170 Pounds
Certifications
AHRI Certified
Yes
AHRI Reference Number
204600301
Warranty Information
Parts Warranty
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
2 Years
Overview
Product Category
Furnace
C84DAMX42U-B
General Information
Type
Evaporator Coil
Refrigerant Type
R-410A
Casing
Uncased
Style
A Coil
Connection Type
Sweat
Configuration
Configuration
Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Downflow
Performance
Capacity
Capacity
Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
3.5 Tons
Cooling BTU
42000
Dimensions
Suction Connection Size
3/8 Inch
Liquid Connection Size
7/8 Inch
Product Height
18 Inches
Product Width
18 1/8 Inches
Product Depth
19 1/2 Inches
Reviews
Revolv RSH3ME42MG2R-045F Reviews & Ratings
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.
Please share your insights with fellow shoppers.
How-To Articles
Understanding Home Heating and Cooling Systems
When you think of a cozy home, you think of a place where you can escape a bitte...
How to Save Money This Cooling Season
The warm weather is here, and it's not leaving any time soon. As the outdoor te...
How to Pick the Perfect Air Conditioner
There are many home cooling options on the market today, but central air condit...
Manuals
Ask A Question!
*Required Fields
+
Thank You For Submitting Your Question
Your submission has been sent successfully. Please give our experts up to two business days to respond.
Media Gallery
Revolv - 3.5 Ton Cooling - 45k BTU/Hr Heating - Heat Pump + Gas Furnace System - 14.3 SEER2 - For Downflow Installation - Front Return
Customer Review Images