Local Pickup FAQ's
SpacePak WCSP-2430D 2-2 1/2 Ton Horizontal Hydronic Fan Coil Air Handler - 30,000 BTU
WCSP-2430D
Features
- SpacePak Blower - Corrosion resistant cabinet with baked enamel finish. Fully insulated with 1-1/2" lb. density bat.
- SpacePak Coil- Six-row copper tube-aluminum fin evaporator coil removes up to 30% more humidity than conventional coil.
- SpacePak Blower Motor - Blower motor is factory-balanced for vibration-free operation.
- SpacePak Drain System - Condensate drain connection in base pan for speciallydesigned, factory-supplied condensate drain assembly.
- SpacePak Controls - Factory-assembled, pre-wired control center with high and low voltage terminal blocks, blower relay and low voltage transformer.
- pacePak Freeze Protection - Factory-installed anti-frost control and thermal expansion valve. Optional factory-installed drain pan float switch.
- SpacePak Unique Connections - Sweat type suction/liquid line connections.
- SpacePak Easy Excess - All Connections located on same side of unit.
- Total comfort solution - cooling and heating
- Uniform temperature - floor to ceiling
- Quiet Performance
- Superior humidity control
- Easy installation - no major remodeling
- Preserves architectural integrity - no large ducting or grills
- Geothermal Application
- Poor indoor air quality is one of the top five most urgent enviornmental risks to public health
- SpacePak offers homeowners so many benefits; it is no wonder that it is the preferred choice for both retrofit and new home construction. Retrofit installations are hassle-free, with no major remodeling. Building a new home? SpacePak installation is even easier as the system is installed with the other rough-ins. And SpacePak gives you added value and versatility for winter warming through a hot water coil, electric coil or heat pump with selected models.
- Unlike conventional central air systems that can require major renovations, SpacePak's flexible, pre-insulated 2" diameter tubing can be threaded through closets or between wall studs or ceiling joints. The whisper-quiet system is run by a blower unit small enough to fit inside an attic, basementor crawlspace.
- Removes up to 30% more moisture from the air than conventional air conditioning systems.Nothing is more uncomfortable than heavy, humid, sticky air. The SpacePak system features an exclusive deep coil design that can remove up 30% more moisture from the air than conventional central air systems. The result is a much lower humidity level that helps you feel cool and comfortable at a higher, more energy efficient thermostat setting.
- Drain Tubing - a tube that drains condensate from the indoor unit to the drain system or outside.
- Secondary Drain Pan AC-BASE-2 - provides protection from water damage of your interior walls or ceiling.
- Diversitech E-Lite Condenser Plastic Pad (optional) - designed as a mounting base for an outdoor units.
- SpacePak AC-ST6-100 R-6 Insulated Supply Tubing 2" ID x 100' attached to main duct work like SPS-PD-6 - square fiberglass main duct trough the plenum take-off with gasket and clips BM-3008 or for round SmartPak AC-SSD duct plenum take-off with gasket and clips AC-TORD. Other side of flexible supply tubing can be connected by using Kwick Connects - SPC-38-10 to Sound Attenuating Tubing BM-6926 or if you have run of the supply tubing longer than 25' you can connect to the Terminator Plate - BM-6845
- SpacePak Outlets - The most important rule of thumb when installing a SpacePak system is having the proper number of outlets. Six (6) to Seven (7) outlets per ton are recommended for optimal 35-40 CFM airflow from each outlet under normal conditions to maximize aspiration.
- SpacePak Outlet Placement - Outlets should be placed in the room where they will create the least disturbance (floors, ceilings, walls) and not infringe upon inhabitants with turbulent air. Traffic patterns, drapes and bed placement are all factors to consider.
- SpacePak Supply Duct - Ideally, all runs should be as equal in length as possible. Keep the 2" duct length between 9 ft. and 30 ft. for best performance. The longer the run, the lower the CFM capacity. See performance chart in installation manual.
- SpacePak Main Trunk/Duct - Maximize use of the main trunkline in order to minimize the lengths of 2" duct. It will allow for an easier installation and better performing, balanced system if 2" duct lines are minimized.
- Spacepak 60/40 Rule - Always try to use a full flow "T" in larger, 4-5 ton systems. Never exceed a 60/40 split of outlets off the main trunkline in order to maintain evenly distributed airflow. A perfect 50/50 split is best.
- SpacePak Take-Offs Location - Distribute takeoffs as evenly as possible along the main trunkline - no closer than 6" away from one another. This will assure better balanced airflow.
- SpacePak Sound Attenuators - The last 3 ft. of every run should use a fully-fabricated SpacePak sound attenuator to reduce outlet air sound.
- SpacePak Return Air Duct - Minimize potential fan noise and maximize performance of this acoustically lined duct by incorporating a 90-degree bend between the air handler and return grille.
- 1 Years parts
The WCSP-2430D series is a horizontal water coil air handler, which can be used with a chiller or boiler plant to provide heating or cooling, or both. The electric duct heater and an additional 2 row hot water coil can also be added as a second stage if required. This unit is also convertible to vertical discharge, but must still lay horizontal. 7/8 water in and out. MEA approval: MEA-119-85-E.
The new SpacePak WCSP-2430D series is a horizontal water coil air handler 2 - 2 1/2 Ton is the result of focus groups with contractors. It features a plastic drain pan with the tappings in front of the coil. The electrical control panel is inside the unit. It has a removable return air rear panel. The TXV and piping has been moved out of the air stream with the connections out the front of the unit, out of the way of the condensate lines.
SpacePak WCSP-2430D 2-2 1/2 Ton of Cooling and 30,000 BTU of Heating Horizontal Hydronic Fan Coil Air Handler at Glance:
The biggest difference between SpacePak, Unico High Velocity Air Systems and other air conditioning systems is the way SpacePak actively circulates air within the room and throughout the structure's entire living/working space. Circulating the air more effectively is what makes a home with SpacePak central air so uniformly comfortable: no cold or warm spots, no drafts, and up to 30% more humidity removed. Conventional central air systems merely drop cold air in at the ceiling; the distribution of cool air is haphazard, leading to over-cooling in some spots or drafts in others. Window air conditioner units or mini-splits require noisy fans within the living space to blow the air around, and there is no overall circulation of the home's air.
Spacepak WCSP-2430G 2-2 1/2 Ton of Cooling and 30,000 BTU of Heating Horizontal Hydronic Fan Coil Air Handler - Fan Coil Unit Features
Spacepak WCSP-2430D 2-2 1/2 Ton of Cooling and 30,000 BTU of Heating Horizontal Hydronic Fan Coil Air Handler Benefits:
Why Should You Have Spacepak WCSP-2430D 2-2 1/2 Ton of Cooling and 30,000 BTU of Heating Horizontal Hydronic Fan Coil Air Handler in Your House?
WCSP-G Series Hydronic Fan Coil SpacePak - Small, Flexible Tubing Instead of Sheet Metal Ductwork
A central heating or cooling system designed to actively circulate air can use smaller ducts than conventional systems; 2 inch mini duct insulated supply tubing keeps the air moving consistently - like pouring water from a pitcher. This smaller duct allows SpacePak to use flexible tubing to distribute the air instead of bulky sheet metal ductwork. This tubing is seamless, so it doesn't waste energy through leaks like sheet metal. And it's flexible, so passages have no corners to accumulate dust, pollen, or mold. The tubing's narrow diameter allows it to be placed in the spaces behind walls, floors, and ceilings: it can be installed with virtually no disruption to livable space, nor to interior architectural features.
SpacePak - Building a new home?
SpacePak installation is even easier as the system is installed with the other rough-ins. And SpacePak gives you added value and versatility for winter warming through a hot water coil, electric coil or heat pump with selected models.
eComfort Note:
To complete Spacepak WCSP-2430D 2-2 1/2 Ton of Cooling and 30,000 BTU of Heating Horizontal Hydronic Fan Coil Air Handler consider to add following accessories that are required to complete the system:
By adding required accessories to Spacepak WCSP-2430D 2-2 1/2 Ton of Cooling and 30,000 BTU of Heating Horizontal Hydronic Fan Coil Air Handler System you are receiving complete cooling and heating solution completely ready for installation. So your contractor does not need to purchase required SpacePak Accessories to finish the installation. Please note that indoor units receive 208-230V power directly from an electrical panel.
SpacePak Installation Tips:
SpacePak AC-ST6-100 R-6 Insulated Supply Tubing 2" ID x 100' Warranty:
Spacepak WCSP-2430D 2-2 1/2 Ton of Cooling and 30,000 BTU of Heating Horizontal Hydronic Fan Coil Air Handler Warranty:
Specifications
Reviews
Please share your insights with fellow shoppers.