Triangle Tube INS110S
Triangle Tube INS110S
Hover to zoom
1 Of 5

Triangle Tube Instinct - 102K BTU - 95% AFUE - Hot Water Gas Boiler - Direct Vent

Model:

INS110S

Write A Review
$2,555.00
Free Shipping
&
Lift Gate
  Learn More About Free Freight
Free Shipping & Lift Gate
*This product qualifies for Free Shipping anywhere in the contiguous US. Accessories may ship separately. Items over 100lbs shipped via semi-truck, be sure to select "Lift Gate" to lower the product to the ground curbside. Remote area surcharges may apply, see our full shipping policy for more details.
In-Stock
Ships Friday, Nov 22nd
Shipping to60601
synchrony card logo
$45 / Month
With our 86 months 11.99% APR*
86 fixed monthly payments required.
Triangle Tube Instinct - 102K BTU - 95% AFUE - Hot Water Gas Boiler - Direct Vent
Triangle Tube Instinct - 102K BTU - 95% AFUE - Hot Water Gas Boiler - Direct Vent
Model: INS110S
$2,555.00
Accessories
Features
Specifications
Reviews
Product Q&A
How-To Articles
Manuals
Share

Recommended Accessories

eComfort expert image
Expert Recommended Accessories Selected by Ken, our Expert
Required Accessories 9
These accessories are required to properly setup/install this product.
Optional Accessories 10

Features

    Triangle Tube is best known for feats of hydronic innovation and incredibly efficient products. The Triangle Tube Instinct is a high-efficiency condensing boiler featuring a fire tube heat exchanger and a market-leading warranty program. The Instinct includes Triangle Tube's CTRLMax Control System for a 60-second setup and simple, plain text operation. An included universal 3-in-1 vent adapter directly accepts PVC, Polypropylene and stainless steel. Available in both solo and combi models, the Instinct boiler is the perfect solution for highly efficient instant or indirect water heating.
  • Fire Tube Heat Exchanger
  • The Instinct boiler features Triangle Tube's stainless steel fire tube heat exchanger, providing a 95% AFUE rating with an impressive 8:1 turndown ratio.
  • CTRLMax Control System
  • The included CTRLMax control system allows boiler setup in 60 seconds. Flexible but easy to use, the CTRLMax system monitors and controls the boiler to operate as efficiently as possible.
  • Extended Warranty
  • Triangle Tube offers two levels of extended warranties for Instinct boilers - up to 6 years for parts and 3 years for labor. Please see the warranty statement under the "Manuals" tab for more information.

Specifications

INS110S
specs product image PID-102838
Overview
Product Category
Boiler
General Information
Product Line
Instinct
Product Category
Boiler
Medium Learn More
Medium
Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type Learn More
Combustion Type
Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Condensing
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
DHW Production Learn More
DHW Production
DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Learn More
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Modulating
Mount Type
Wall
Minimum Altitude
0 Feet
Maximum Altitude
10000 Feet
Includes Pump
No
Assembly Type
Packaged
Gas Conversion Kit
Included
Performance
AFUE Learn More
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
95 %
Maximum Input Capacity Learn More
Maximum Input Capacity
The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
110000 BTU
Minimum Input Capacity
13750 BTU
DOE Heating Capacity Learn More
DOE Heating Capacity
Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
102000 BTU
Net I=B=R Capacity Learn More
Net I=B=R Capacity
I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
89000 BTU
Ultra Low NOx Emissions Learn More
Ultra Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Low NOx Emissions Learn More
Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
No
Turndown Ratio
8:1
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
3 Inches
Gas Connection Size
3/4 Inch
Boiler Supply
1 Inch
Boiler Return
1 Inch
Product Height
26 Inches
Product Width
21 3/4 Inches
Product Depth
16 1/2 Inches
Product Weight
75 Pounds
Certifications
CSA Listed
Yes
Energy Star Listed
Yes
ASME Certified
Yes
AHRI Certified
Yes
AHRI Reference Number
204469772
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
2 Years
Heat Exchanger Warranty
10 Years

Reviews

Triangle Tube INS110S Reviews & Ratings
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.

Product Q&A

Expert avatar photo
Be the First to Ask A Question Answered by Ken, the eComfort Product Expert

How-To Articles

How to Pick the Perfect Boiler
How to Pick the Perfect Boiler
At the heart of every boiler heating system is the boiler itself. It's responsi...
Five Ways to Improve Boiler Efficiency
Five Ways to Improve Boiler Efficiency
When purchasing a new boiler for your home, efficiency is the name of the game....
Hydronic System Accessory Guide
Hydronic System Accessory Guide
How warm does a coat keep you without gloves and a hat? Accessories are sometim...
eComfort How-To Library
eComfort How-To Library
Articles, Tips and Buying Guides from Our Experts

Manuals

 
Media Gallery
Triangle Tube Instinct - 102K BTU - 95% AFUE - Hot Water Gas Boiler - Direct Vent
Triangle Tube INS110S
Customer Review Images