Triangle Tube KS 500
Triangle Tube KS 500
Hover to zoom
1 Of 5

Triangle Tube Keystone - 500,000 BTU - Hot Water Boiler - NG - 95% EFF - Direct Vented - 0 to 2,000 Ft. Altitude

Model:

KS 500

Write A Review
Product Discontinued
Sorry, this product is no longer available.
Triangle Tube Keystone - 500,000 BTU - Hot Water Boiler - NG - 95% EFF - Direct Vented - 0 to 2,000 Ft. Altitude
Triangle Tube Keystone - 500,000 BTU - Hot Water Boiler - NG - 95% EFF - Direct Vented - 0 to 2,000 Ft. Altitude
Model: KS 500
Product Discontinued
Accessories
Features
Specifications
Reviews
How-To Articles
Manuals
Share

Recommended Accessories

eComfort expert image
Expert Recommended Accessories Selected by Ken, our Expert
Required Accessories 9
These accessories are required to properly setup/install this product.
Optional Accessories 10

Features

    Triangle Tube is best known for two things: feats of hydronic innovation and incredibly efficient products. If you are looking for those qualities in your hot water boiler, the Keystone certainly fits the bill. The Keystone is a high-efficiency, condensing boiler for large spaces. The condensing technology behind the Keystone will capture and reuse gaseous heat that escapes traditional boilers. Stainless steel construction of the heat exchanger and an internal condensate trap will protect the KS 500 from corrosion. The Keystone's modulating burner scales heat production based on your needs and reduces unnecessary energy consumption. All told, the Keystone is an incredibly reliable and efficient water heating solution.

    Product Features

    Pre-Mix Burner
    The pre-mix burner on Keystone boilers means that your heating will be environmentally friendly and clean. Pre-mixing the fuel improves air quality and reduces NOx output to less than ten parts per million, well within the strictest low NOx guidelines.

    Easy Setup
    Keystone boilers include several features that streamline the installation process. A large, easy-to-use display and consolidated connections at the top of the unit make setting up a Keystone quick and simple.

    Communicating
    Up to eight Keystone units may be staged together through the Keystone's controls. This allows you to expand your water heating to accommodate the largest of applications without sacrificing efficiency. The Keystone's controls also support integration into building automation systems.

    PID Staging
    The Keystone uses Proportional, Integral, Derivative (PID) logic for staging. PID staging will consider three things when deciding to activate a boiler: how far the water temperature is from the target temperature, how long the temperature has been there, and how quickly the temperature is changing. PID logic improves efficiency and averts temperature drops in your HVAC system.

    Product Includes
    • (1) Triangle Tube KS 500 Hot Water Boiler
    • (1) Outdoor Reset Sensor
    • (1) Natural Gas to Liquid Propane Conversion Kit

Specifications

KS 500
specs product image PID-23087
General Information
Product Line
Keystone
Medium Learn More
Medium
Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type Learn More
Combustion Type
Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Condensing
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
DHW Production Learn More
DHW Production
DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Learn More
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Modulating
Connection Type
NPT
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
2000 Feet
Assembly Type
Packaged
Gas Conversion Kit
Included
Performance
Maximum Input Capacity Learn More
Maximum Input Capacity
The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
500000 BTU
Minimum Input Capacity
100000 BTU
Efficiency Type
Thermal Efficiency
Efficiency
95 %
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
4 Inches
Supply Connection
1 1/2 Inches
Return Connection
1 1/2 Inches
Product Height
38 Inches
Product Width
24 1/2 Inches
Product Depth
37 Inches
Product Weight
381 Pounds
Certifications
CSA Listed
Yes
ASME Certified
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
5297141
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
10 Years

Reviews

Triangle Tube KS 500 Reviews & Ratings
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.

How-To Articles

How to Pick the Perfect Boiler
How to Pick the Perfect Boiler
At the heart of every boiler heating system is the boiler itself. It's responsi...
Five Ways to Improve Boiler Efficiency
Five Ways to Improve Boiler Efficiency
When purchasing a new boiler for your home, efficiency is the name of the game....
Hydronic System Accessory Guide
Hydronic System Accessory Guide
How warm does a coat keep you without gloves and a hat? Accessories are sometim...
eComfort How-To Library
eComfort How-To Library
Articles, Tips and Buying Guides from Our Experts

Manuals

 
Media Gallery
Triangle Tube Keystone - 500,000 BTU - Hot Water Boiler - NG - 95% EFF - Direct Vented - 0 to 2,000 Ft. Altitude
Triangle Tube KS 500
Customer Review Images