Local Pickup FAQ's
Hover to zoom
1 Of 5
Weil-McLain CGa-6-PIDN - 146K BTU - 83.2% AFUE - Hot Water Gas Boiler - Chimney Vent (Scratch & Dent)
Model:
381357808-SD
+
Share This Product
Recommended Accessories
Expert Recommended Accessories
Selected by Ken, our Expert
Required Accessories
9
These accessories are required to properly setup/install this product.
Optional Accessories
10
Features
- Efficiency-Boosting Insulation
- Heat retention is critical to energy efficiency. Heat leakage represents energy use without any comfort gains. An extended, insulated steel jacket prevents heat from escaping the CGa and improves the efficiency.
- Durable Construction
- Reliability is one of the greatest ways a boiler can provide value. Weil-McLain wanted to be sure that you'll enjoy the comfort the CGa provides for years to come. With a steel base and burners and cast-iron boiler sections, they have done just that.
- Product Includes
- (1) Weil-McLain CGa-6-PIDN Hot Water Boiler
- (1) Taco 007 Circulator
- (1) Vent Damper
- (1) Draft Hood
***Scratch & Dent*** Dents on top and side panels. Over the last 130 years, Weil-McLain has built a reputation of designing some of the most reliable boilers in the marketplace. Their dedication to producing lasting heating solutions is seen in every boiler they make. The CGa is a compact, natural draft boiler. The low profile makes this boiler perfect for space conscious applications with chimney access. Solid construction and a good efficiency rating make the CGa an excellent value. A vent damper, draft hood, and Taco circulator are included. These components, coupled with easily accessible controls, make it easy to install and set your CGa up. Whether you are replacing an older boiler or beginning new construction, the CGa is an efficient, compact heating solution.
California residents see
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
For more information go to: www.p65Warnings.ca.gov
Specifications
381357808-SD
General Information
Product Line
CGa
Medium
Medium
Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Cast Iron
Fuel Type
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type
Combustion Type
Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Conventional
Vent Type
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
DHW Production
DHW Production
DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Staging
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
4500 Feet
Assembly Type
Packaged
Includes Pump
Yes
Gas Conversion Kit
Available
UPC
672619189416
Performance
AFUE
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
83.2 %
Maximum Input Capacity
Maximum Input Capacity
The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
175000 BTU
DOE Heating Capacity
DOE Heating Capacity
Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
146000 BTU
Net I=B=R Capacity
Net I=B=R Capacity
I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
127000 BTU
Ultra Low NOx Emissions
Ultra Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
1/2 Inch
Flue Connection Size
6 Inches
Supply Connection
1 1/4 Inches
Return Connection
1 1/4 Inches
Product Height
28 3/8 Inches
Product Width
19 Inches
Product Depth
23 1/4 Inches
Shipping Height
31 1/2 Inches
Shipping Width
27 1/2 Inches
Shipping Depth
33 Inches
Shipping Weight
325 Pounds
Certifications
Country of Origin
United States
CSA Listed
Yes
ASME Certified
Yes
AHRI Certified
Yes
AHRI Reference Number
2101648
Warranty Information
Parts Warranty
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
2 Years
Heat Exchanger Warranty
20 Years
Reviews
(17)
Weil-McLain 381357808-SD Reviews & Ratings
How-To Articles
How to Pick the Perfect Boiler
At the heart of every boiler heating system is the boiler itself. It's responsi...
Five Ways to Improve Boiler Efficiency
When purchasing a new boiler for your home, efficiency is the name of the game....
Hydronic System Accessory Guide
How warm does a coat keep you without gloves and a hat? Accessories are sometim...
Manuals
Ask A Question!
*Required Fields
+
Thank You For Submitting Your Question
Your submission has been sent successfully. Please give our experts up to two business days to respond.
Media Gallery
Weil-McLain CGa-6-PIDN - 146K BTU - 83.2% AFUE - Hot Water Gas Boiler - Chimney Vent (Scratch & Dent)
Customer Review Images