Weil-McLain CGi-6-PIN - 135K BTU - 84.0% AFUE - Hot Water Gas Boiler - Power Vent

Model:

381359008

Write A Review
$3,866.00
Free Shipping
&
Lift Gate
  Learn More About Free Freight
Free Shipping & Lift Gate
*This product qualifies for Free Shipping anywhere in the contiguous US. Accessories may ship separately. Items over 100lbs shipped via semi-truck, be sure to select "Lift Gate" to lower the product to the ground curbside. Remote area surcharges may apply, see our full shipping policy for more details.
In-Stock
Ships Friday, Dec 27th
Shipping to60601
synchrony card logo
$68 / Month
With our 86 months 11.99% APR*
86 fixed monthly payments required.
Weil-McLain CGi-6-PIN - 135K BTU - 84.0% AFUE - Hot Water Gas Boiler - Power Vent
Weil-McLain CGi-6-PIN - 135K BTU - 84.0% AFUE - Hot Water Gas Boiler - Power Vent
Model: 381359008
$3,866.00
Accessories
Features
Specifications
Reviews
Product Q&A
How-To Articles
Manuals
Share

Recommended Accessories

eComfort expert image
Expert Recommended Accessories Selected by Ken, our Expert
Required Accessories 9
These accessories are required to properly setup/install this product.
Optional Accessories 10

Features

    Over the last 130 years, Weil-McLain has built a reputation of designing some of the most reliable boilers in the marketplace. Their dedication to producing lasting heating solutions is seen in every boiler they make. The CGi represents excellent durability and efficiency in a space conscious package. Supporting both natural and induced draft venting, this is the perfect boiler for any application regardless of chimney access. The CGi is designed in a way that does not require a vertical draft hood, keeping the low profile that makes this boiler so attractive. Whether you are replacing an older boiler or beginning new construction, the CGi is an efficient, compact heating solution.
  • Efficiency-Boosting Insulation
  • Heat retention is critical to energy efficiency. Heat leakage represents energy use without any comfort gains. An extended, insulated steel jacket prevents heat from escaping the CGi and improves the efficiency.
  • Durable Construction
  • Reliability is one of the greatest ways a boiler can provide value. Weil-McLain wanted to be sure that you'll enjoy the comfort the CGi provides for years to come. With a steel base and burners and cast-iron boiler sections, they have done just that.
  • Additional Features
  • Integrated Low Water Cutoff
  • Integrated Boiler Control Module with Intermittent Electronic Ignition System
  • Cast Iron Sections with Built-in Air Separator
  • Insulated Extended Steel Jacket
California residents see
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
For more information go to: www.p65Warnings.ca.gov

Specifications

381359008
specs product image PID-109141
Overview
Product Category
Boiler
UPC
672619214187
General Information
Product Line
CGi
Product Category
Boiler
Medium Learn More
Medium
Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Cast Iron
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type Learn More
Combustion Type
Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Conventional
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Power Vent
DHW Production Learn More
DHW Production
DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Learn More
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Staging
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
2000 Feet
Assembly Type
Packaged
Includes Pump
Yes
Gas Conversion Kit
Available
Performance
AFUE Learn More
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
84 %
Maximum Input Capacity Learn More
Maximum Input Capacity
The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
158000 BTU
DOE Heating Capacity Learn More
DOE Heating Capacity
Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
135000 BTU
Net I=B=R Capacity Learn More
Net I=B=R Capacity
I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
117000 BTU
Ultra Low NOx Emissions Learn More
Ultra Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
3 Inches
Gas Connection Size
1/2 Inch
Supply Connection
1 1/4 Inches
Return Connection
1 1/4 Inches
Product Height
28 3/8 Inches
Product Width
19 Inches
Product Depth
23 1/4 Inches
Product Weight
335 Pounds
Shipping Width
27 1/2 Inches
Shipping Height
31 1/2 Inches
Shipping Depth
33 Inches
Shipping Weight
335 Pounds
Certifications
Country of Origin
United States
CSA Listed
Yes
ASME Certified
Yes
AHRI Reference Number
205261854
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
2 Years
Heat Exchanger Warranty
20 Years

Reviews

Weil-McLain 381359008 Reviews & Ratings
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.

Product Q&A

Expert avatar photo
Be the First to Ask A Question Answered by Ken, the eComfort Product Expert

How-To Articles

How to Pick the Perfect Boiler
How to Pick the Perfect Boiler
At the heart of every boiler heating system is the boiler itself. It's responsi...
Five Ways to Improve Boiler Efficiency
Five Ways to Improve Boiler Efficiency
When purchasing a new boiler for your home, efficiency is the name of the game....
Hydronic System Accessory Guide
Hydronic System Accessory Guide
How warm does a coat keep you without gloves and a hat? Accessories are sometim...
eComfort How-To Library
eComfort How-To Library
Articles, Tips and Buying Guides from Our Experts

Manuals

 
Media Gallery
Weil-McLain CGi-6-PIN - 135K BTU - 84.0% AFUE - Hot Water Gas Boiler - Power Vent
Weil-McLain 381359008
Customer Review Images