On Sale

Weil-McLain 382200610
Weil-McLain 382200610
Hover to zoom
1 Of 5

Weil-McLain GV90+3 - 65K BTU - 91.9% AFUE - Hot Water Gas Boiler - Direct Vent

Model:

382200610

Write A Review
$3,693.00
Was $3,888.00
Free Shipping
&
Lift Gate
  Learn More About Free Freight
Free Shipping & Lift Gate
*This product qualifies for Free Shipping anywhere in the contiguous US. Accessories may ship separately. Items over 100lbs shipped via semi-truck, be sure to select "Lift Gate" to lower the product to the ground curbside. Remote area surcharges may apply, see our full shipping policy for more details.
In-Stock
Ships Monday, Dec 23rd
Shipping to60601
synchrony card logo
$65 / Month
With our 86 months 11.99% APR*
86 fixed monthly payments required.
Weil-McLain GV90+3 - 65K BTU - 91.9% AFUE - Hot Water Gas Boiler - Direct Vent
Weil-McLain GV90+3 - 65K BTU - 91.9% AFUE - Hot Water Gas Boiler - Direct Vent
Model: 382200610
$3,693.00
Was $3,888.00
Accessories
Features
Specifications
Reviews
Product Q&A
How-To Articles
Manuals
Share

Recommended Accessories

eComfort expert image
Expert Recommended Accessories Selected by Ken, our Expert
Required Accessories 9
These accessories are required to properly setup/install this product.
Optional Accessories 10

Features

    Over the last 130 years, Weil-McLain has built a reputation of designing some of the most reliable boilers in the marketplace. Their dedication to producing lasting heating solutions is seen in every boiler they make. The GV90+ is a testament to their dedication to durability. A steel base and jacket are combined with cast-iron sections to make one of the most rugged high efficiency boilers in the marketplace. Condensing technology allows the GV90+ to capture gases expelled by traditional boilers and reuse the heat that these gases contain, saving you energy and expense. Getting your GV90+ up and running is simple; the boiler control features snap in connections and venting can be achieved through a direct vent, direct exhaust, or concentric vent system. The GV90+ is a boiler that will save you money for years into the future, the boiler's high efficiency and durability see to that.
  • Dual Heat Exchangers
  • A cast-iron primary exchanger provides reliable heat and peace of mind with its tremendous durability. The secondary exchanger is made from stainless steel to resist the corroding effect of condensation.
  • Multi-Pass Efficiency
  • A five pass primary exchanger and two pass secondary exchanger improve the heat transfer surface area of the boiler. By facilitating heat transfer in this manner, the GV90+ is getting more heat out of less energy, improving system efficiency and comfort.
  • Dual Circulators
  • The GV90+ includes a bypass circulator and system circulator. Including two circulators allows the GV90+ to accept low temperature return water that would damage other boilers, expanding the possible applications for the boiler right out of the box.
  • Extra Wide Waterways
  • The design of the GV90+ includes extra wide waterways. These channels are a blessing for older systems where debris may be present. Wider waterways improve flow within the boiler and prevent buildup which can limit efficiency.
California residents see
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
For more information go to: www.p65Warnings.ca.gov

Specifications

382200610
specs product image PID-49650
Overview
Product Category
Boiler
UPC
0672619195202
General Information
Product Line
GV90+
Product Category
Boiler
Medium Learn More
Medium
Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Cast Iron
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type Learn More
Combustion Type
Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Condensing
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
DHW Production Learn More
DHW Production
DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Learn More
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Staging
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
5500 Feet
Assembly Type
Packaged
Includes Pump
Yes
Gas Conversion Kit
Included
Performance
AFUE Learn More
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
91 %
Maximum Input Capacity Learn More
Maximum Input Capacity
The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
70000 BTU
DOE Heating Capacity Learn More
DOE Heating Capacity
Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
65000 BTU
Net I=B=R Capacity Learn More
Net I=B=R Capacity
I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
56000 BTU
Ultra Low NOx Emissions Learn More
Ultra Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
3 Inches
Gas Connection Size
1/2 Inch
Supply Connection
1 Inch
Return Connection
1 Inch
Product Height
30 3/4 Inches
Product Width
16 Inches
Product Depth
30 3/4 Inches
Product Weight
313 Pounds
Shipping Weight
313 Pounds
Certifications
Country of Origin
United States
Energy Star Listed
Yes
CSA Listed
Yes
ASME Certified
Yes
AHRI Certified
Yes
AHRI Reference Number
4615194
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
2 Years
Heat Exchanger Warranty
20 Years

Reviews

(6)
Weil-McLain 382200610 Reviews & Ratings

Product Q&A

(2)
Expert avatar photo
Product Questions Answered by Ken, the eComfort Product Expert
What is the reason for a "12" max" connecting pipes between the output and input of a boiler? I have a multi-zone system with one circulator on the return line to the boiler. Does the internal circulator use this pipe to heat up the return water?
Denis 
from New York 
October 30, 2016
Will the Weil-McLaine GV90+ convert to propane? Is the adapter included for the switch from NG to propane?
Shelley 
from New York 
July 14, 2016

How-To Articles

How to Pick the Perfect Boiler
How to Pick the Perfect Boiler
At the heart of every boiler heating system is the boiler itself. It's responsi...
Five Ways to Improve Boiler Efficiency
Five Ways to Improve Boiler Efficiency
When purchasing a new boiler for your home, efficiency is the name of the game....
Hydronic System Accessory Guide
Hydronic System Accessory Guide
How warm does a coat keep you without gloves and a hat? Accessories are sometim...
eComfort How-To Library
eComfort How-To Library
Articles, Tips and Buying Guides from Our Experts

Manuals

 
Media Gallery
Weil-McLain GV90+3 - 65K BTU - 91.9% AFUE - Hot Water Gas Boiler - Direct Vent
Weil-McLain 382200610
Customer Review Images