Local Pickup FAQ's
Hover to zoom
1 Of 5
GE Concealed Duct 4-Zone System - 36,000 BTU Outdoor - 7k + 7k + 12k + 18k Indoor - 17.0 SEER
Model:
GE4L36D07071218
+
Share This Product
Recommended Accessories
Expert Recommended Accessories
Selected by Ken, our Expert
Required Accessories
9
These accessories are required to properly setup/install this product.
Optional Accessories
10
Features
- Inverter Technology
- The Endure Series features leading A-PAM DC Inverter Technology to provide efficient and quiet operation. The inverter is used to continuously regulate refrigerant flow and ensure there's no wasted energy.
- Low Ambient Heating
- With the ability to provide heat at ambient temperatures reaching -15° F, the Endure Series won't leave you hanging when it gets cold outside.
- Quiet Operation
- The Endure Series concealed duct units feature a quiet mode that operates at a sound level down to 21 dB.
- Blue Fin Coating
- The Endure Series outdoor unit features a special coating to whisk away condensate water, preventing rust and extending its lifespan.
- Warm Start
- GE's hot start technology prevents cold drafts by delaying fan operation until the heat exchanger has warmed up.
- Recommended line set sizes for indoor unit connectivity:
- AD07SL2VHB: 1/4" x 3/8" Line Set (Qty 2)
- AD12SL2VHB: 1/4" x 3/8" Line Set
- AD18SL2VHB: 1/4" x 1/2" Line Set
- Built-In WiFi
- (1) GE - 36k BTU - Endure Series Outdoor Condenser - For 2-4 Zones (ASH436NCDWA)
- (1) GE - 18k BTU - Endure Series Concealed Duct Unit - For Multi-Zone (AD18SL2VHB)
- (1) GE - 12k BTU - Endure Series Concealed Duct Unit - For Multi-Zone (AD12SL2VHB)
- (2) GE - 7k BTU - Endure Series Concealed Duct Unit - For Multi-Zone (AD07SL2VHB)
- (4) GE - Non-Programmable Wired Controller (QACT17A)
- Line Set - This double insulated tubing transfers refrigerant efficiently between your outdoor condenser and indoor units.
- Drain Tubing - Drain tubing facilitates the reliable and effective removal of condensate from your system. It connects your indoor units to drain locations of your choosing.
- Disconnect Box & Electrical Whip Kit - The Disconnect Box & Whip Kit provides a safe and simple way to connect your outdoor condenser to your fuse box.
- Connecting Wire - This durable, insulated wire provides power to your indoor units from your outdoor condenser.
- Outdoor Condenser Plastic Pad or Wall Bracket - We recommend outdoor condensers should not be placed directly on the ground. An outdoor condenser pad or wall bracket will provide a stable way to mount your condenser free from obstructions and debris.
A common challenge for mini split systems installed in frigid environments is the ability to effectively produce heat in subzero temperatures. Enter the Endure Multi Series from GE. Including state-of-the-art mini split technology, the Endure Multi Series will produce heat down to an impressive -15° F. The concealed duct unit features the slimmest design in the industry while remaining incredibly quiet. A remote controller is included with each indoor unit for your convenience. Persevere through the frigid winter and hot summer months with the Endure Multi Series from GE.
Product Includes
Product Note
Each indoor unit will include any port adapters necessary for multi-zone installation.This product requires the following accessories for installation:
California residents see
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
For more information go to: www.p65Warnings.ca.gov
Specifications
Product Includes
- (1) GE - 36k BTU - Endure Series Outdoor Condenser - For 2-4 Zones (ASH436NCDWA)
- (1) GE - 18k BTU - Endure Series Concealed Duct Unit - For Multi-Zone (AD18SL2VHB)
- (1) GE - 12k BTU - Endure Series Concealed Duct Unit - For Multi-Zone (AD12SL2VHB)
- (2) GE - 7k BTU - Endure Series Concealed Duct Unit - For Multi-Zone (AD07SL2VHB)
- (4) GE - Non-Programmable Wired Controller (QACT17A)
GE4L36D07071218
Overview
Product Category
Mini Split Heat Pump System
General Information
Type
Concealed Duct
Product Line
Endure Series
Product Category
Mini Split Heat Pump System
Operating Mode
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Number of Zones
Number of Zones
A zone is a room or area within a building that has its own temperature control.
4
Refrigerant Type
R-410A
Indoor Unit Size(s)
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
7 + 7 + 12 + 18
Outdoor Unit Size
36000 BTU
DOE Regional Compliance
DOE Regional Compliance
In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Performance
SEER
SEER
SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
17.0
EER
EER
EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
10.0
HSPF
HSPF
HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
10.5
Cooling Power Input
2740 Watts
Heating Power Input
2710 Watts
Low Ambient Heating
Yes
Minimum Outdoor Temperature for Heating
Minimum Outdoor Temperature for Heating
This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
-15 F
Minimum Outdoor Temperature for Cooling
23 F
Dimensions
Product Weight
357.3 Pounds
Shipping Weight
418.4 Pounds
Certifications
ETL Listed
Yes
Energy Star Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
205782853
ASH436NCDWA
General Information
Type
Outdoor Condenser
Product Line
Endure Series
Product Category
Mini Split System Components
Operating Mode
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Maximum Number of Zones
4
Multi-Zone Compatible
Yes
Refrigerant Type
R-410A
Installation Location
Outdoor
Performance
Cooling BTU
36000
Maximum Sound Level
Maximum Sound Level
Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
59 dB
Low Ambient Heating
Yes
Minimum Outdoor Temperature for Heating
Minimum Outdoor Temperature for Heating
This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
-15 F
Minimum Outdoor Temperature for Cooling
14 F
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
40 Amps
Dimensions
Maximum Line Length
230 Feet
Line Set A Liquid Connection
1/4 Inch
Line Set A Gas Connection
3/8 Inch
Line Set B Liquid Connection
1/4 Inch
Line Set B Gas Connection
3/8 Inch
Line Set C Liquid Connection
1/4 Inch
Line Set C Gas Connection
3/8 Inch
Line Set D Liquid Connection
1/4 Inch
Line Set D Gas Connection
1/2 Inch
Product Height
33 1/8 Inches
Product Width
37 3/8 Inches
Product Depth
13 3/8 Inches
Product Weight
198.4 Pounds
Shipping Weight
215 Pounds
Certifications
ETL Listed
Yes
UL Listed
Yes
Warranty Information
Parts Warranty
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Compressor Warranty
7 Years
Overview
Product Category
Mini Split System Components
AD18SL2VHB
General Information
Type
Concealed Duct
Product Line
Endure Series
Product Category
Mini Split System Components
Operating Mode
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Multi-Zone Compatible
Yes
Refrigerant Type
R-410A
Indoor Unit Size(s)
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
18
Installation Location
Indoor
Performance
Cooling BTU
18000
Cooling Capacity
18000 BTU
Maximum Air Flow
540 CFM
Minimum Air Flow
306 CFM
Minimum Sound Level
25 dB
Maximum Sound Level
Maximum Sound Level
Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
31 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
1/4 Inch
Liquid Connection Size
1/2 Inch
Product Height
7 1/2 Inches
Product Width
33 1/2 Inches
Product Depth
16 1/2 Inches
Product Weight
48.5 Pounds
Shipping Weight
61.8 Pounds
Certifications
ETL Listed
Yes
Warranty Information
Parts Warranty
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Overview
Product Category
Mini Split System Components
AD12SL2VHB
General Information
Type
Concealed Duct
Product Line
Endure Series
Product Category
Mini Split System Components
Operating Mode
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Multi-Zone Compatible
Yes
Refrigerant Type
R-410A
Indoor Unit Size(s)
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
12
Installation Location
Indoor
Performance
Cooling BTU
12000
Cooling Capacity
12000 BTU
Maximum Air Flow
400 CFM
Minimum Air Flow
218 CFM
Minimum Sound Level
23 dB
Maximum Sound Level
Maximum Sound Level
Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
38 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
1/4 Inch
Liquid Connection Size
3/8 Inch
Product Height
7 1/2 Inches
Product Width
33 1/2 Inches
Product Depth
16 1/2 Inches
Product Weight
36.8 Pounds
Shipping Weight
47.2 Pounds
Certifications
ETL Listed
Yes
Warranty Information
Parts Warranty
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Overview
Product Category
Mini Split System Components
AD07SL2VHB
General Information
Type
Concealed Duct
Product Line
Endure Series
Product Category
Mini Split System Components
Operating Mode
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Multi-Zone Compatible
Yes
Refrigerant Type
R-410A
Indoor Unit Size(s)
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
7
Installation Location
Indoor
Performance
Cooling BTU
7000
Cooling Capacity
7000 BTU
Maximum Air Flow
353 CFM
Minimum Air Flow
188 CFM
Minimum Sound Level
21 dB
Maximum Sound Level
Maximum Sound Level
Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
35 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
1/4 Inch
Liquid Connection Size
3/8 Inch
Product Height
7 1/2 Inches
Product Width
33 1/2 Inches
Product Depth
16 1/2 Inches
Product Weight
36.8 Pounds
Shipping Weight
47.2 Pounds
Certifications
ETL Listed
Yes
Warranty Information
Parts Warranty
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Overview
Product Category
Mini Split System Components
QACT17A
General Information
Type
Wired Remote
Product Line
Endure Series
Product Category
Mini Split Accessories
Overview
Product Category
Mini Split Accessories
Reviews
GE Mini Splits GE4L36D07071218 Reviews & Ratings
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.
Please share your insights with fellow shoppers.
How-To Articles
How to Pick the Perfect Mini Split Floor Mounted Indoor Unit
If you are installing a mini split system but you don't have enough clearance f...
What You Should Know About Mini-Split Wiring
Although they are easier to install than central air conditioning systems, mini...
How to Pick the Perfect Mitsubishi Mini-Split Condenser
If you're struggling to keep your home or office comfortable, you are not alone...
Manuals
Ask A Question!
*Required Fields
+
Thank You For Submitting Your Question
Your submission has been sent successfully. Please give our experts up to two business days to respond.
Media Gallery
GE Concealed Duct 4-Zone System - 36,000 BTU Outdoor - 7k + 7k + 12k + 18k Indoor - 17.0 SEER
Customer Review Images