On Sale

Williams 4007331
Williams 4007331
Williams 4007331
Hover to zoom
1 Of 5
Williams 4007331
Williams 4007331

Williams Forsaire - 40k BTU - Propane Direct-Vent Wall Furnace - 76.5% AFUE - Intermittent Pilot

Model:

4007331

Write A Review
$1,925.10
Was $2,139.00
Closeout Item Icon
Closeout Item
Free Shipping
&
Lift Gate
  Learn More About Free Freight
Free Shipping & Lift Gate
*This product qualifies for Free Shipping anywhere in the contiguous US. Accessories may ship separately. Items over 100lbs shipped via semi-truck, be sure to select "Lift Gate" to lower the product to the ground curbside. Remote area surcharges may apply, see our full shipping policy for more details.
Only 2 In-Stock
Ships Friday, Nov 22nd
Shipping to60601
synchrony card logo
$321 / Month
Suggested monthly payments with 6 month financing.
Williams Forsaire - 40k BTU - Propane Direct-Vent Wall Furnace - 76.5% AFUE - Intermittent Pilot
Williams Forsaire - 40k BTU - Propane Direct-Vent Wall Furnace - 76.5% AFUE - Intermittent Pilot
Model: 4007331
$1,925.10
Was $2,139.00
Accessories
Features
Specifications
Reviews
Product Q&A
How-To Articles
Manuals
Share

Recommended Accessories

eComfort expert image
Expert Recommended Accessories Selected by Ken, our Expert
Required Accessories 9
These accessories are required to properly setup/install this product.
Optional Accessories 10

Features

    Safety is no worry with this furnace, having a matchless pilot igniter and sealed combustion chamber requiring no inside air. Whether recessed into the wall or surface mounted, the soft-white powder coated finish provides a discrete durable finish that blends into any home's decor.
  • Sealed Combustion
  • Rather than using indoor air to fuel combustion, the Williams direct vent pulls intake air directly from the outdoors. This means the heat your furnace generates isn't fed back into the system, maximizing efficiency.
  • Counterflow Blower System
  • The Forsaire furnace has a counterflow blower system that takes air from the ceiling and blows the warm air at the floor. This allows for the heat to be evenly distributed throughout the room.
  • Safe Pilot Ignition
  • With matchless pilot ignition, the guess work is taken out of lighting the furnace. By sealing the pilot and igniter away from dirt and debris, the electronic igniter lights the furnace safely and reliably.
  • Vent Limit Safety Switch
  • The vent limit safety switch is equipped on all Forsaire furnaces. This turns off the unit in case the vent is blocked, protecting your family from carbon monoxide and fires.
  • Product Includes
  • All Vent Materials Needed for a 9" Thick Wall
  • Product Note
    A thermostat does not come included with this unit and is required. The Williams P322016 thermostat is compatible and can be found under the "Accessories" tab. Alternatively, any standard millivolt thermostat can be used.
California residents see
Warning: This product can expose you to chemicals including Epichlorohydrin which is known to the State of California to cause Cancer.
For more information go to: www.p65Warnings.ca.gov

Specifications

4007331
specs product image PID-71200
Overview
Product Category
Furnace
UPC
0093909298913
General Information
Type
Gas Wall Furnace
Product Line
Forsaire
Product Category
Furnace
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Liquid Propane
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Learn More
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Blower Motor Type
Single Speed
Mount Type
Wall
Gas Conversion Kit
Available
Performance
AFUE Learn More
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
76.5 %
Heating BTU
40000
High Fire Input
40000 BTU
High Fire Output
32000 BTU
Maximum Air Flow
325 CFM
Electrical Data
Minimum Circuit Ampacity
2 Amps
Dimensions
Gas Connection Size
1/2 Inch
Product Height
77 3/8 Inches
Product Width
14 1/8 Inches
Product Depth
11 3/4 Inches
Product Weight
116 Pounds
Shipping Weight
126 Pounds
Certifications
CSA Listed
Yes
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
10 Years

Reviews

(16)
Williams 4007331 Reviews & Ratings

Product Q&A

Expert avatar photo
Be the First to Ask A Question Answered by Ken, the eComfort Product Expert

How-To Articles

How Gas Furnaces Work
How Gas Furnaces Work
Do you wish you had a better grasp on things when the heat goes out and your fa...
Choosing Between a Furnace and a Heat Pump
Choosing Between a Furnace and a Heat Pump
The battle between furnaces and heat pumps is hot right now. Although most Amer...
How to Pick the Perfect Furnace
How to Pick the Perfect Furnace
The heart of nearly every forced air heating system is the furnace. Gas furnace...
eComfort How-To Library
eComfort How-To Library
Articles, Tips and Buying Guides from Our Experts

Manuals

 
Media Gallery
Williams Forsaire - 40k BTU - Propane Direct-Vent Wall Furnace - 76.5% AFUE - Intermittent Pilot
Williams 4007331
Williams 4007331
Williams 4007331
Customer Review Images